F6 · PowerFlex 40
For F6 · PowerFlex 40, brand is Allen-Bradley; model / series is PowerFlex 40; fault code is F6; fault name is Motor Stalled; cause is Drive is unable to accelerate motor, verified against its source on 2026-09-01.
- Brand
- Allen-Bradley
- Model / series
- PowerFlex 40
- Fault code
- F6 verified
- Fault name
- Motor Stalled verified
- Cause
- Drive is unable to accelerate motor. verified
- Corrective action
- Increase P039…A067 [Accel Time x] or reduce load so drive output current does not exceed the current set by parameter A089 [Current Limit 1]. verified
Verified
Review by
What the source says
F6 Motor Stalled
— literature.rockwellautomation.com, retrieved 2026-09-01
Where each value comes from
This source states these in separate places, so each value is shown with the passage that states it.
Cause
Drive is unable to accelerate motor.
Corrective action
Increase P039…A067 [Accel Time x] or reduce load so drive output current does not exceed the current set by parameter A089 [Current Limit 1].
— all from literature.rockwellautomation.com, retrieved 2026-09-01
Source
- literature.rockwellautomation.comhttps://literature.rockwellautomation.com/idc/groups/literature/documents/um/22b-um001_-en-e.pdf