End2 · GA800 · Auto-Tuning Error
For End2 · GA800 · Auto-Tuning Error, brand is Yaskawa; model / series is GA800; fault code is End2; fault name is Iron Core Saturation Coefficient; type is Auto-Tuning Error, verified against its source on 2026-09-01.
- Brand
- Yaskawa
- Model / series
- GA800
- Fault code
- End2 verified
- Fault name
- Iron Core Saturation Coefficient verified
- Type
- Auto-Tuning Error verified
- Cause
- The motor nameplate data entered during Auto- Tuning is incorrect. verified
- Corrective action
- • Make sure that the input motor nameplate data is correct. • Do Auto-Tuning again and correctly set the motor nameplate data. verified
What the source says
End2 Iron Core Saturation Coefficient Flashing Auto-Tuning Error 141
— yaskawa.com, retrieved 2026-09-01
Where each value comes from
This source states these in separate places, so each value is shown with the passage that states it.
Cause
The motor nameplate data entered during Auto- Tuning is incorrect.
Corrective action
• Make sure that the input motor nameplate data is correct. • Do Auto-Tuning again and correctly set the motor nameplate data.
— all from yaskawa.com, retrieved 2026-09-01
Source
- yaskawa.comhttps://www.yaskawa.com/delegate/getAttachment?documentId=TOEPYAIGA8001&cmd=documents&documentName=TOEPYAIGA8001.pdf