Reference Source

LT-3 · GA800 · Alarm

For LT-3 · GA800 · Alarm, brand is Yaskawa; model / series is GA800; fault code is LT-3; fault name is SoftChargeBypassRelay MainteTime; type is Alarm, verified against its source on 2026-09-01.

Brand
Yaskawa
Model / series
GA800
Fault code
LT-3 verified
Fault name
SoftChargeBypassRelay MainteTime verified
Type
Alarm verified
Cause
The soft charge bypass relay is at 90% of its expected performance life. verified
Corrective action
Replace the control board or the drive. verified
Sourceyaskawa.com
Verified
Review by
DatasetIndustrial VFD fault and alarm codes by brand

What the source says

LT-3 (0043) SoftChargeBypassRelay MainteTime Flashing Alarm 130

yaskawa.com, retrieved 2026-09-01

Where each value comes from

This source states these in separate places, so each value is shown with the passage that states it.

Cause

The soft charge bypass relay is at 90% of its expected performance life.

Corrective action

Replace the control board or the drive.

— all from yaskawa.com, retrieved 2026-09-01

Source

Last verified against source: . Due for re-check by . This page as Markdown · OKF bundle · full dataset as JSON.