LT-2 · GA800 · Alarm
For LT-2, model / series is GA800; type is Alarm; brand is Yaskawa; fault name is Capacitor Maintenance Time; cause is The capacitors for the main circuit and control circuit are at 90% of expected performance life, verified against its source on 2026-10-10.
- Brand
- Yaskawa
- Model / series
- GA800
- Fault code
- LT-2 verified
- Fault name
- Capacitor Maintenance Time verified
- Type
- Alarm verified
- Cause
- The capacitors for the main circuit and control circuit are at 90% of expected performance life. verified
- Corrective action
- Replace the control board or the drive. verified
What the source says
LT-2 (0036) Capacitor Maintenance Time Flashing Alarm 130
— yaskawa.com, retrieved 2026-09-01
Where each value comes from
This source states these in separate places, so each value is shown with the passage that states it.
Cause
The capacitors for the main circuit and control circuit are at 90% of expected performance life.
Corrective action
Replace the control board or the drive.
— all from yaskawa.com, retrieved 2026-09-01
Source
- yaskawa.comhttps://www.yaskawa.com/delegate/getAttachment?documentId=TOEPYAIGA8001&cmd=documents&documentName=TOEPYAIGA8001.pdf