Reference Source

CP1 · GA800 · Alarm

For CP1, model / series is GA800; type is Alarm; brand is Yaskawa; fault name is Comparator 1 Limit Error; cause is The monitor value set in H2-20 [Comparator 1 Monitor Selection] was in the range of H2-21 [Comparator 1 Lower Limit] and H2-22 [Comparator 1 Upper Limit], verified against its source on 2026-10-10.

Brand
Yaskawa
Model / series
GA800
Fault code
CP1 verified
Fault name
Comparator 1 Limit Error verified
Type
Alarm verified
Cause
The monitor value set in H2-20 [Comparator 1 Monitor Selection] was in the range of H2-21 [Comparator 1 Lower Limit] and H2-22 [Comparator 1 Upper Limit]. verified
Corrective action
Examine the monitor value and remove the cause of the fault. verified
Sourceyaskawa.com
Verified
Review by
DatasetIndustrial VFD fault and alarm codes by brand

What the source says

CP1 (0087) Comparator 1 Limit Error Flashing Alarm 125

— yaskawa.com, retrieved 2026-09-01

Where each value comes from

This source states these in separate places, so each value is shown with the passage that states it.

Cause

The monitor value set in H2-20 [Comparator 1 Monitor Selection] was in the range of H2-21 [Comparator 1 Lower Limit] and H2-22 [Comparator 1 Upper Limit].

Corrective action

Examine the monitor value and remove the cause of the fault.

— all from yaskawa.com, retrieved 2026-09-01

Source

Last verified against source: . Due for re-check by . This page as Markdown · OKF bundle · full dataset as JSON.