Reference Source

Solar inverter–battery compatibility

Which lithium batteries have been tested with which solar inverter brands for closed-loop BMS communication, from the inverter and battery manufacturers' own published compatibility lists. Each record names the inverter brand, the battery brand and model, the communication protocol (CAN, RS485, etc.), minimum firmware versions required, system types supported (off-grid, backup, ESS), and any noted restrictions. Answers 'will battery X talk to inverter Y' — the question the scenario research found assistants hedge on with 'check the manufacturer's compatibility PDF' rather than stating the pairing.

Records101
Sources28
Verified
Review by
Licencefactual compilation from manufacturer published compatibility documents; facts cited with attributed quotes, no document reproduced

11 records where two or more sources state different values. Both sides are reproduced on the record page, each with its own source and quote.

The data

Battery modelInverter brandBattery brandNominal voltageCommunication interfaceSupported system typesRestrictions or notesMinimum firmwareModule capacity
AXIstorage Li 7S / 9SVictronAXIstorage48VCAN-busESSidentical with the BMZ ESS hardware and software
B-Box L 3.5-14.0VictronBYD48VCAN-busESS, Grid BackupOff-Grid: noVenus OS v2.423.5 kWh
B-Box Premium LVL 15.4VictronBYD48VCAN-busESS, Grid Backup, Off-gridVenus OS v2.5215.36 kWh
B-Box Premium LVS 4.0VictronBYD48VCAN-busESS, Grid Backup, Off-gridVenus OS v2.524.0 kWh
B-Box Pro 2.5-10.0VictronBYD48VCAN-busESS, Grid Backup, Off-gridVenus OS v2.422.5 kWh
BatteryBox LV5.0GoodWeBYD48VCANOn-grid
BatteryBox LV5.0+GoodWeBYD48VCANOn-grid
BattleBorn LiFePO4VictronBattleBornNone (drop-in)Open-loop onlythere is no integration or communication, such CANbus, between the BattleBorn battery and the Victron system. Such communication is not required; and also not available. The BattleBorn batteries are self-contained drop-in style batteries.
BlueNova Energy LiFePo4VictronBlueNova Energy48VCAN-busOff Grid, Backup, Energy StorageGX device v2.02
BSLBATT LiFePO4VictronBSLBATTBMS-CanESS, Grid Backup
Discover AES RACKMOUNTVictronDiscoverCAN-busESS, Grid Backup, Off-grid
DL5.0CGoodWeDyness48VCANOn-gridARM firmware versions 06 and above
Dyness LiFePO4VictronDyness48VBMS-Can (500 kbit/s)ESS, Grid Backup, Off-gridVenus OS v3.31
DYNESS-LV x1GoodWeDyness48VCANOn-gridARM firmware versions 07 and above
EBick LVVictronCegasa48VCAN-busESS, Grid Backup, Off-grid13.5 kWh
EBick LV 15VictronCegasa48VCAN-busESS, Grid Backup, Off-grid15 kWh
ESS 7.0VictronBMZ48VCAN-busESSBMZ batteries can only be used in a Victron ESS installation installation that uses the ESS Assistant.GX device v1.72
ESS 9.0VictronBMZ48VCAN-busESSBMZ batteries can only be used in a Victron ESS installation installation that uses the ESS Assistant.GX device v1.72
ESS XVictronBMZ48VCAN-busESSBMZ batteries can only be used in a Victron ESS installation installation that uses the ESS Assistant.GX device v1.72
ESS ZVictronBMZ48VCAN-busESSBMZ batteries can only be used in a Victron ESS installation installation that uses the ESS Assistant.GX device v1.72
Firefly-7.2KGoodWeTecloman48VCANOn-gridARM firmware versions 12 and above
Force-H1GoodWePylontechCANOn-gridARM firmware versions 14 and above
Force H1/H2sources differSolisPylontechCANOn/off-grid
Force H1/H2-V2sources differSMA Solar Technology AGPylontechCANOn/off-gridOnly Force-H1-V2 and Force-H2-V2 are compatible with SMA Sunny Boy Storage inverters mentioned in the list above.04.04.03.R
Force-H3sources differSol-ArkPylontechCANOn/off-grid1066
Force-L1GoodWePylontech48VCANOn-gridARM firmware versions 07 and above
Force-L1 & L2VictronPylontech48VCAN-busESS, Grid Backup, Off-gridVenus OS v3.503.55 kWh
Force-L1/L2SMA Solar Technology AGPylontech48VCANOn/off-gridWhen compatible with SMA SI4.4-M / SI6.0-H / SI8.0-H, it`s required to follow the min. configuration table from SMA for a guaranteed configuration. The Force L1/L2 is not compatible with SMA SI series.
Freedom Won LiTE and eTowerVictronFreedom Won48VCAN-busESS, Grid Backup, Off-gridFreedom Won battery warranties require that you have configured the battery correctly.
Hubble LithiumVictronHubble LithiumCAN-bus via CloudLinkRequires CloudLink
HVB 14.8GoodWeBYDCANOn-gridFor HVB multi-tower system parallel connections, the BYD 70A combiner box is required.
HVL 12.0GoodWeBYDCANOn-gridFor U.S onlyARM firmware versions 11 and above
HVM 11.0GoodWeBYDCANOn-gridARM firmware versions 11 and above
HVM+ 11.0GoodWeBYDCANOn-grid
HVS 5.1GoodWeBYDCANOn-gridARM firmware versions 11 and above
HVS+ 5.1GoodWeBYDCANOn-gridFor HVS+ multi-tower system parallel connections, the BYD 70A combiner box is required.
L051100-AGoodWeUZENERGY48VCANOn-gridARM firmware versions 12 and above
LBS051100A-A02GoodWeOLOID48VCANOn-gridARM firmware versions 12 and above
LBS102100AGoodWeOLOIDCANOn-gridARM firmware versions 14 and above
Leoch LiFePO4VictronLeoch48VBMS-Can (500 kbit/s)
LITE 30GoodWeBYDCANOn-grid
LV Flex 5VictronBYD48VCAN-busESS, Grid Backup, Off-gridVenus OS v2.525.0 kWh
LV5.0+VictronBYD48VCAN-busESS, Grid Backup, Off-gridVenus OS v2.525.12 kWh
LVL 15.4GoodWeBYD48VCANOn-gridARM firmware versions 07 and above
LX A5.0-10GoodWeGoodWeCANOn-grid
LX A5.0-30GoodWeGoodWeCANOn-grid
LX C101-10GoodWeGoodWeCANOn-grid
LX F13.1-HGoodWeGoodWeCANOn-gridARM firmware versions 19 and above
LX F6.6-HGoodWeGoodWeCANOn-gridARM firmware versions 19 and above
LX F9.6-30GoodWeGoodWeCANOn-gridFor U.S onlyARM firmware versions 24 and above and DSP versions 07 and above
LX F9.8-HGoodWeGoodWeCANOn-gridARM firmware versions 19 and above
LX U5.0-30GoodWeGoodWeCANOn-gridARM firmware versions 34 and above
LX U5.4-LGoodWeGoodWeCANOn-gridARM firmware versions 11 and above
LXD5.0-10GoodWeGoodWeCANOn-grid
M48112-PGoodWeAlpha48VCANOn-gridCAN communication line sequence of ALPHA-ESS battery does not match GoodWe inverters. A matching solution provided by ALPHA-ESS is required.ARM firmware versions 11 and above
MeterBoost LiFePO4VictronMeterBoostBMS-Can (500 kbit/s) or VE.Can (250 kbit/s)
MG Energy Systems lithium-ionVictronMG Energy SystemsCAN-bus
Mint-JKE10GoodWeiPotisEdgeCANOn-gridARM firmware versions 12 and above
Pelio-Lsources differVictronPylontech51.2VCAN-busESS, Grid Backup, Off-gridVenus OS v3.505.12kWh
Phantom-Ssources differVictronPylontech48VCAN-busESS, Grid Backup, Off-gridVenus OS v3.50
POWER BOX G2GoodWeDyness48VCANOn-gridARM firmware versions 08 and above
POWERBOX F-5.0GoodWeDyness48VCANOn-gridARM firmware versions 07 and above
Powercube-M1CDelios s.r.l.PylontechCANOn/off-gridV3.00
Powercube X1/X2/H1/H2sources differIngeteam Power TechnologyPylontechCANOn/off-gridABH1002AA
Pytes LiFePO4VictronPytes48VBMS-Can (500 kbit/s)minimum supported Pytes firmware version is 1.10.18GX v3.31
RESU 10GoodWeLG48VCANOn-gridARM firmware versions 00 and above
RESU 13GoodWeLG48VCANOn-gridARM firmware versions 07 and above
RESU 6.5GoodWeLG48VCANOn-gridARM firmware versions 00 and above
RESU10H PrimeGoodWeLGCANOn-gridARM firmware versions 20 and above and DSP versions 02 and above
RESU16H PrimeGoodWeLGCANOn-gridARM firmware versions 20 and above and DSP versions 02 and above
Rolls LFPVictronRollsCAN-bus
SECU-S13GoodWeGoodWeCANOn-gridFor U.S onlyARM firmware versions 14 and above
SimpliPhi LiFePO4VictronSimpliPhi PowerNone (drop-in)Off-grid, diesel-hybridthere is no control wiring required or software integration required
SMILE5-BATGoodWeAlpha48VCANOn-gridCAN communication line sequence of ALPHA-ESS battery does not match GoodWe inverters. A matching solution provided by ALPHA-ESS is required.ARM firmware versions 10 and above
SOLARMD SS074/SS4037/SS202VictronSOLARMD48VCAN-busOff-grid, Backup, Energy Storage
Soluna 10K Pack HVGoodWeSolunaCANOn-gridARM firmware versions 10 and above
Soluna 5K PackGoodWeSoluna48VCANOn-grid
Soluna LiFePO4VictronSoluna48VBMS-Can (500 kbit/s)minimum supported Soluna firmware version is JC3.30GX v3.60
Sonnenschein Module Pro LIBM0480050-G01VictronExide48VCAN-busSonnenschein Module Pro LIBM0480050-G01 as of firmware v1.10Venus OS v2.90
SSS StorageDOCK ES RangeVictronSSSCAN-bus
SSS StorageDOCK LV-Com RangeVictronSSSCAN-bus
STACK100GoodWeDynessCANOn-gridET15-30K only supports 5-13 modules of STACK100 batteries, the inverter will be damaged if the number of batteries does not match.ARM firmware versions 08 and above
Sunwoda LiFePO4VictronSunwoda48VBMS-Can (500 kbit/s)minimum supported Sunwoda firmware version is V1.11GX v3.60
Tab e.module L5.1VictronTabBMS-CanTesting was completed with TAB e.module L5.1 running BMS firmware version 0.3.5 and Cerbo GX running VenusOS v3.63VenusOS v3.63
Tower Pro TP11GoodWeDynessCANOn-gridARM firmware versions 10 and above
Tower T10GoodWeDynessCANOn-gridARM firmware versions 10 and above
UF5000sources differVictronPylontech51.2VCAN-busESS, Grid Backup, Off-gridVenus OS v3.50Coming soon
UP2500VictronPylontech24VCAN-busESS, Grid Backup, Off-gridUP2500N A 01V00101 does not have a CANBUS port, and IS NOT supported by Victron. UP2500N B 01V00101 released April 2020 has the CANBUS port and IS supported.Venus OS v3.502.55 kWh
UP5000sources differSelectronicPylontech48VCANOn/off-grid
UP5000 & US5000(B)VictronPylontech48VCAN-busESS, Grid Backup, Off-gridVenus OS v3.504.8 kwh
US2000sources differGoodWePylontech48VCANOn-gridNot Compatible with Pelio-L and UF5000.
US2000 (Plus/C/D)VictronPylontech48VCAN-busESS, Grid Backup, Off-gridVenus OS v3.502.4 kWh
US2000CDeyePylontech48VCANOn/off-gridV1586
US2000V2Alpha & Outback EnergyPylontech48VRS485 (9600)Off-grid91.24
US3000sources differSchneider-ElectricPylontech48VCANOn/off-gridGateway: V1.06 XW+ Pro: V1.04
US3000(C)VictronPylontech48VCAN-busESS, Grid Backup, Off-gridVenus OS v3.503.5 kWh
US3000CSolisPylontech48VCANOn/off-grid90009
US5000sources differVictron EnergyPylontech48VCANOn/off-gridWhen compatible with Victron Multi/Quattro in off-grid application via Venus-device, it is requried to have a Victron MPPT or other compatible PV inverter with Victron to avoid the system getting shut down.422/V2.15
US5000-BImeon EnergyPylontech48VCANOn/off-gridV1.7.6.5
WeCo LiFePO4VictronWeCo48VBMS-Can (500 kbit/s)Connecting a WeCo battery to the GX device will force enable DVCC and SVS, and disable STS.GX v3.31
ZYC Energy LiFePO4VictronZYC Energy48VBMS-Can (500 kbit/s)

Where this came from

Every record above links the page it was taken from and quotes the sentence that states it. These are the 28 sources this dataset was assembled from.

Machine-readable

101 records. last verified against source . due for re-check by .

Licence. factual compilation from manufacturer published compatibility documents; facts cited with attributed quotes, no document reproduced