F13 · PowerFlex 40
For F13 · PowerFlex 40, brand is Allen-Bradley; model / series is PowerFlex 40; fault code is F13; fault name is Ground Fault; cause is A current path to earth ground has been detected at one or more of the drive output terminals, verified against its source on 2026-09-01.
- Brand
- Allen-Bradley
- Model / series
- PowerFlex 40
- Fault code
- F13 verified
- Fault name
- Ground Fault verified
- Cause
- A current path to earth ground has been detected at one or more of the drive output terminals. verified
- Corrective action
- Check the motor and external wiring to the drive output terminals for a grounded condition. verified
Verified
Review by
What the source says
F13 Ground Fault
— literature.rockwellautomation.com, retrieved 2026-09-01
Where each value comes from
This source states these in separate places, so each value is shown with the passage that states it.
Cause
A current path to earth ground has been detected at one or more of the drive output terminals.
Corrective action
Check the motor and external wiring to the drive output terminals for a grounded condition.
— all from literature.rockwellautomation.com, retrieved 2026-09-01
Source
- literature.rockwellautomation.comhttps://literature.rockwellautomation.com/idc/groups/literature/documents/um/22b-um001_-en-e.pdf