Reference Source

oPE20 · GA800 · Parameter Setting Error

For oPE20 · GA800 · Parameter Setting Error, brand is Yaskawa; model / series is GA800; fault code is oPE20; fault name is PG-F3 Setting Error; type is Parameter Setting Error, verified against its source on 2026-09-01.

Brand
Yaskawa
Model / series
GA800
Fault code
oPE20 verified
Fault name
PG-F3 Setting Error verified
Type
Parameter Setting Error verified
Cause
The value set in F1-01 [Encoder 1 Pulse Count (PPR)] does not agree with the number of encoder pulses. verified
Corrective action
• Examine the F1-01 value and the number of encoder pulses. • Set F1-01 correctly. verified
Sourceyaskawa.com
Verified
Review by
DatasetIndustrial VFD fault and alarm codes by brand

What the source says

oPE20 PG-F3 Setting Error Flashing Parameter Setting Error 139

yaskawa.com, retrieved 2026-09-01

Where each value comes from

This source states these in separate places, so each value is shown with the passage that states it.

Cause

The value set in F1-01 [Encoder 1 Pulse Count (PPR)] does not agree with the number of encoder pulses.

Corrective action

• Examine the F1-01 value and the number of encoder pulses. • Set F1-01 correctly.

— all from yaskawa.com, retrieved 2026-09-01