Reference Source

oFC02 · GA800 · Fault

For oFC02, model / series is GA800; type is Fault; brand is Yaskawa; fault name is Duplicate Options; cause is The same option cards or the same type of option cards are connected to connectors CN5-A, B, and C, verified against its source on 2026-10-10.

Brand
Yaskawa
Model / series
GA800
Fault code
oFC02 verified
Fault name
Duplicate Options verified
Type
Fault verified
Cause
The same option cards or the same type of option cards are connected to connectors CN5-A, B, and C. verified
Corrective action
Connect the option card to the correct connector. verified
Sourceyaskawa.com
Verified
Review by
DatasetIndustrial VFD fault and alarm codes by brand

What the source says

oFC02 (0303) Duplicate Options Illuminated Fault 112

— yaskawa.com, retrieved 2026-09-01

Where each value comes from

This source states these in separate places, so each value is shown with the passage that states it.

Cause

The same option cards or the same type of option cards are connected to connectors CN5-A, B, and C.

Corrective action

Connect the option card to the correct connector.

— all from yaskawa.com, retrieved 2026-09-01

Source

Last verified against source: . Due for re-check by . This page as Markdown · OKF bundle · full dataset as JSON.