Reference Source

LSo · GA800 · Fault

For LSo · GA800 · Fault, brand is Yaskawa; model / series is GA800; fault code is LSo; fault name is Low Speed Motor Step-Out; type is Fault, verified against its source on 2026-09-01.

Brand
Yaskawa
Model / series
GA800
Fault code
LSo verified
Fault name
Low Speed Motor Step-Out verified
Type
Fault verified
Cause
The motor code set incorrectly. verified
Corrective action
• Set E5-01 [PM Motor Code Selection] correctly as specified by the motor. • For specialized motors, refer to the motor test report and set E5- xx correctly. verified
Sourceyaskawa.com
Verified
Review by
DatasetIndustrial VFD fault and alarm codes by brand

What the source says

LSo (0051) Low Speed Motor Step-Out Illuminated Fault 105

yaskawa.com, retrieved 2026-09-01

Where each value comes from

This source states these in separate places, so each value is shown with the passage that states it.

Cause

The motor code set incorrectly.

Corrective action

• Set E5-01 [PM Motor Code Selection] correctly as specified by the motor. • For specialized motors, refer to the motor test report and set E5- xx correctly.

— all from yaskawa.com, retrieved 2026-09-01

Source

Last verified against source: . Due for re-check by . This page as Markdown · OKF bundle · full dataset as JSON.