FbH · GA800 · Fault
For FbH · GA800 · Fault, brand is Yaskawa; model / series is GA800; fault code is FbH; fault name is Excessive PID Feedback; type is Fault, verified against its source on 2026-09-01.
- Brand
- Yaskawa
- Model / series
- GA800
- Fault code
- FbH verified
- Fault name
- Excessive PID Feedback verified
- Type
- Fault verified
- Cause
- The FbH detection level is set incorrectly. verified
- Corrective action
- Adjust b5-36 [PID High Feedback Detection Lvl] and b5-37 [PID High Feedback Detection Time]. verified
What the source says
FbH (0041) Excessive PID Feedback Illuminated Fault 103
— yaskawa.com, retrieved 2026-09-01
Where each value comes from
This source states these in separate places, so each value is shown with the passage that states it.
Cause
The FbH detection level is set incorrectly.
Corrective action
Adjust b5-36 [PID High Feedback Detection Lvl] and b5-37 [PID High Feedback Detection Time].
— all from yaskawa.com, retrieved 2026-09-01
Source
- yaskawa.comhttps://www.yaskawa.com/delegate/getAttachment?documentId=TOEPYAIGA8001&cmd=documents&documentName=TOEPYAIGA8001.pdf