E5 · GA800 · Fault

For E5 · GA800 · Fault, brand is Yaskawa; model / series is GA800; fault code is E5; fault name is MECHATROLINK Watchdog Timer Err; type is Fault, verified against its source on 2026-09-01.

Brand
Yaskawa
Model / series
GA800
Fault code
E5 verified
Fault name
MECHATROLINK Watchdog Timer Err verified
Type
Fault verified
Cause
The drive detected a watchdog circuit exception while it received data from the controller. verified
Corrective action
Examine the MECHATROLINK cable connection. verified
Sourceyaskawa.com
Verified
Review by
DatasetIndustrial VFD fault and alarm codes by brand

What the source says

E5 (0039) MECHATROLINK Watchdog Timer Err Illuminated Fault 101

yaskawa.com, retrieved 2026-09-01

Where each value comes from

This source states these in separate places, so each value is shown with the passage that states it.

Cause

The drive detected a watchdog circuit exception while it received data from the controller.

Corrective action

Examine the MECHATROLINK cable connection.

— all from yaskawa.com, retrieved 2026-09-01