For 29 · FC 301/302 · ALARM, brand is Danfoss; model / series is FC 301/302; fault code is 29; fault name is Heat Sink temp; type is ALARM, verified against its source on 2026-09-01.

Brand
Danfoss
Model / series
FC 301/302
Fault code
29 verified
Fault name
Heat Sink temp verified
Type
ALARM verified
Cause
The maximum temperature of the heat sink is exceeded. The temperature fault is not reset until the temperature drops below a defined heat sink temperature. The trip and reset points are different based on the frequency converter power size. verified
Corrective action
Check for the following conditions: • The ambient temperature is too high. • The motor cables are too long. • Incorrect airflow clearance above and below the frequency converter. • Blocked airflow around the frequency converter. • Damaged heat sink fan. • Dirty heat sink. verified
Sourcefiles.danfoss.com
Verified
Review by
DatasetIndustrial VFD fault and alarm codes by brand

What the source says

ALARM 29, Heat Sink temp

files.danfoss.com, retrieved 2026-09-01

Where each value comes from

This source states these in separate places, so each value is shown with the passage that states it.

Cause

The maximum temperature of the heat sink is exceeded. The temperature fault is not reset until the temperature drops below a defined heat sink temperature. The trip and reset points are different based on the frequency converter power size.

Corrective action

Check for the following conditions: • The ambient temperature is too high. • The motor cables are too long. • Incorrect airflow clearance above and below the frequency converter. • Blocked airflow around the frequency converter. • Damaged heat sink fan. • Dirty heat sink.

— all from files.danfoss.com, retrieved 2026-09-01

Source

Last verified against source: . Due for re-check by . This page as Markdown · OKF bundle · full dataset as JSON.