How often does this cylinder or tank have to be retested?

67 records covering 52 container specifications, one fact each. Every value is transcribed from the source that states it and carries the sentence it was taken from: 5 sources across 2 sites, last checked 2026-09-30, due for re-check by 2027-08-06. Every record is listed below, each linking the page its value came from.

Records67
Sources5
Verified
Review by
LicenceFacts extracted from the US Code of Federal Regulations, a US government work not subject to copyright. Text is read via law.cornell.edu for historical reasons (eCFR used to block our fetcher; retested 2026-09-24 and it no longer does), and via govinfo where Cornell's rendering mangles a typeset fraction; the fact is the regulation's, not the host's, and each record quotes a short verbatim span and links back to the section.

About this data

Mandatory requalification, retest and inspection intervals for pressure containers under 49 CFR Part 180, with the qualifier that decides which interval applies. Each record is one container specification under one test type, stating the interval in years and the condition attached to it. Covers cylinders (49 CFR 180.209), cargo tanks (180.407), intermediate bulk containers (180.352) and portable tanks (180.605). Answers 'how often does a scuba tank need hydro testing', 'DOT 3AL requalification 5 years or 12', 'IBC tote retest interval 2.5 years', 'MC-331 propane cargo tank internal visual inspection frequency', and 'when does a DOT 3AA cylinder qualify for the 10 year star'. The interval is a property of the specification, the service and the configuration together, not of the container alone, and the exceptions are where the answers go wrong: DOT 3AL is 5 or 12 years depending on service, and an MC-331 under 3,500 gallons in dedicated propane service built from non-quenched-and-tempered SA-612 gets 10 years where every other cargo tank gets 5. Past the due date the container may not be filled and offered for transportation.

The data

Container specificationTest or inspectionIntervalMinimum test pressureRegulation sectionCondition or service qualifier
3Periodic requalification5.3000 psig49 CFR § 180.209
3A, 3AAPeriodic requalification5, 10, or 125/3 times service pressure, except non-corrosive service49 CFR § 180.209
3ALPeriodic requalification5 or 125/3 times service pressure49 CFR § 180.209
3AX, 3AAXPeriodic requalification5.5/3 times service pressure49 CFR § 180.209
3B, 3BNPeriodic requalification5 or 102 times service pressure49 CFR § 180.209
3EPeriodic requalificationTest not required49 CFR § 180.209
3HTPeriodic requalification35/3 times service pressure49 CFR § 180.209
3TPeriodic requalification5.5/3 times service pressure or UE49 CFR § 180.209
4AA480Periodic requalification5 or 102 times service pressure49 CFR § 180.209
4B, 4BA, 4BW, 4B-240ETPeriodic requalification5, 7, 10, or 122 times service pressure, except non-corrosive service49 CFR § 180.209
4D, 4DA, 4DSPeriodic requalification5.2 times service pressure49 CFR § 180.209
4EPeriodic requalification5, 10, or 122 times service pressure, except non-corrosive service49 CFR § 180.209
4LPeriodic requalificationTest not required49 CFR § 180.209
8, 8ALPeriodic requalification10 or 2049 CFR § 180.209
a specification listed in the table in this paragraph (g)complete external visual inspectionat five-year intervals after the first inspection49 CFR § 180.209used exclusively in the service indicated
All cargo tanksExternal Visual Inspection6 months.49 CFR § 180.407designed to be loaded by vacuum with full opening rear heads
All cargo tanksPressure Test2 years.49 CFR § 180.407designed to be loaded by vacuum with full opening rear heads
All cargo tanksInternal Visual Inspection1 year.49 CFR § 180.407transporting lading corrosive to the tank
All cargo tanksPressure Test1 year.49 CFR § 180.407which are insulated with no manhole or insulated and lined, except MC 338
All insulated cargo tanks, except MC 330, MC 331, MC 338Internal Visual Inspection1 year.49 CFR § 180.407
All lined cargo tanksLining Inspection1 year.49 CFR § 180.407transporting lading corrosive to the tank
All other cargo tanksExternal Visual Inspection1 year.49 CFR § 180.407
All other cargo tanksPressure Test5 years.49 CFR § 180.407
All other cargo tanks, except MC 338Internal Visual Inspection5 years.49 CFR § 180.407
All other cargo tanks except MC 338Leakage Test1 year.49 CFR § 180.407
all unlined cargo tanksThickness testingannually49 CFR § 180.407cargo tanks measuring less than the sum of the minimum prescribed thickness, plus one-fifth of the original corrosion allowance
All unlined cargo tanksThickness Test2 years.49 CFR § 180.407transporting material corrosive to the tank, except MC 338
DOT 3A, 3A480X, or 4AA480Periodic requalificationevery 10 years instead of every five years49 CFR § 180.209used exclusively for anhydrous ammonia, commercially free from corroding components, and protected externally by a suitable corrosion-resistant coating (such as paint)
DOT 3A, 3AA, 3B, 4BA, or 4BWPeriodic requalificationevery 10 years instead of every five years49 CFR § 180.209used exclusively for methyl bromide
DOT 3A, 3AA, or 3ALwater-jacket or direct expansion method12 years after the original test date and at 12-year intervals thereafter49 CFR § 180.209used as a fire extinguisher
DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B. DOT 4AA480, DOT 4B, DOT 4BA, DOT 4BWExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Cyclopropane that is commercially free from corroding components
DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BWExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Butadiene, inhibited, that is commercially free from corroding components
DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4EExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Liquefied hydrocarbon gas that is commercially free of corroding components
DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4EExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Liquefied petroleum gas that meets the detail requirements limits in Table 1 of ASTM 1835, Standard Specification for Liquefied Petroleum (LP) Gases
DOT 3A, DOT 3AA, DOT 3A480X, DOT 4AA480External visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Anhydrous ammonia of at least 99.95% purity
DOT 3A, DOT 3AA, DOT 3A480X, DOT 4B, DOT 4BA, DOT 4BW, DOT 4EExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Chlorinated hydrocarbons and mixtures thereof that are commercially free from corroding components
DOT 3A, DOT 3AA, DOT 3A480X, DOT 4B, DOT 4BA, DOT 4BW, DOT 4EExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Fluorinated hydrocarbons and mixtures thereof that are commercially free from corroding components
DOT 3A, DOT 3AA, DOT 3B, DOT 4B, DOT 4BA, DOT 4BWExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Anhydrous mono, di, trimethylamines that are commercially free from corroding components
DOT 3A, DOT 3AA, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4EExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Methylacetylene-propadiene, stabilized, that is commercially free from corroding components
DOT 3A, DOT 3AA, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4EExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Propylene that is commercially free from corroding components
DOT 3A or 3AAPeriodic requalificationevery ten years instead of every five years49 CFR § 180.209removed from any cluster, bank, group, rack, or vehicle each time it is filled
DOT-3AL Cylinders Made of Aluminum Alloy 6351-T6Eddy current examination combined with visual inspection549 CFR § 180.209
DOT-3AL cylinders manufactured of 6351-T6 aluminum alloyrequalified and inspected for sustained load cracking49 CFR § 180.209used in self-contained underwater breathing apparatus (SCUBA), self-contained breathing apparatus (SCBA), or oxygen service
DOT 4B, 4BA, 4B240ET or 4BWproof-pressure testby the end of 12 years after the original test date and at seven (7) year intervals49 CFR § 180.209a water capacity over 5.44 kg (12 pounds)
DOT 4B, 4BA, 4B240ET or 4BWwater-jacket or direct expansion testby the end of 12 years after the original test date and at 12-year intervals theafter49 CFR § 180.209a water capacity over 5.44 kg (12 pounds)
DOT 4B, 4BA, 4B240ET or 4BWwater-jacket, direct expansion or proof pressure test methodsby the end of 12 years after the original test date and at 12-year intervals thereafter49 CFR § 180.209used as a fire extinguisher, with a water capacity of 5.44 kg (12 pounds) or less
DOT 4B240, DOT 4BW240External visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Ethyleneimine, stabilized
DOT 4BWExternal visual inspectionat five-year intervals after the first inspection49 CFR § 180.209Alkali metal alloys, liquid, n.o.s., Alkali metal dispersions or Alkaline earth metal dispersions, Potassium, Potassium Sodium alloys and Sodium that are commercially free of corroding components
DOT-8 seriesPorous filler requalification5 to 20 years49 CFR § 180.209On or after January 1, 1991
DOT-8 seriesShell (visual inspection) requalification10 years49 CFR § 180.209On or after January 1, 1991
DOT Specifications 4B, 4BA, 4BW, or 4Evolumetric expansion testingevery 12 years instead of every 5 years49 CFR § 180.209protected externally by a suitable corrosion-resistant coating and used exclusively for non-corrosive gas that is commercially free from corroding components
Exemption or special permit cylinderPeriodic requalificationSee current exemption or special permitSee current exemption or special permit49 CFR § 180.209
flexible, fiberboard, or wooden IBCsVisual inspectionprior to first use and permitted reuse49 CFR § 180.352
Foreign cylinderPeriodic requalification5As marked on cylinder, but not less than 5/3 of any service or working pressure marking49 CFR § 180.209
IM or UN portable tankinitial inspection and testbefore being placed into service49 CFR § 180.605
IM or UN portable tankintermediate periodic inspection and testat least every 2.5 years following the initial inspection and the last 5 year periodic inspection and test49 CFR § 180.605
IM or UN portable tankperiodic inspection and testat least once every 5 years49 CFR § 180.605
MC 330 and MC 331Leakage Test2 years.49 CFR § 180.407in chlorine service
MC 330 and MC 331Pressure Test2 years.49 CFR § 180.407in chlorine service
MC 331Internal Visual Inspection10 years.49 CFR § 180.407less than 3,500 gallons water capacity in dedicated propane service constructed of nonquenched and tempered NQT SA-612 steel
MC 331Pressure Test10 years.49 CFR § 180.407less than 3,500 gallons water capacity in dedicated propane service constructed of nonquenched and tempered NQT SA-612 steel
metal, rigid plastic and composite IBCinternal inspectionat least every five years49 CFR § 180.352
metal, rigid plastic, and composite IBCsexternal visual inspectioninitially after production and every 2.5 years49 CFR § 180.352
metal, rigid plastic, and composite IBCsleakproofness testprior to its first use in transportation and every 2.5 years thereafter49 CFR § 180.352intended to contain solids that are loaded or discharged under pressure or intended to contain liquids
Specification 51 portable tankperiodic inspection and testat least once every five years49 CFR § 180.605
Specification 56 or 57 portable tankperiodic inspection and testat least once every 2.5 years49 CFR § 180.605
Specification 60 portable tankperiodic inspection and testat the end of the first 4-year period after the original test; at least once every 2 years thereafter up to a total of 12 years of service; and at least once annually thereafter49 CFR § 180.605Retesting is not required on a rubber-lined tank except before each relining

Where this came from

Every record above links the page it was taken from and quotes the sentence that states it. These are the 5 sources this dataset was assembled from.

Machine-readable

From your own code

Same records, same quotes, without scraping the page: refsource is on PyPI and npm. Each value comes back carrying the URL it was read from and the sentence on that page that states it — .source and .quote sit on the value itself rather than in a side channel, so the checking step is available instead of skipped.

pip install refsource
refsource lookup hazmat-container-retest-intervals test_type="Periodic requalification"

npx -y refsource lookup hazmat-container-retest-intervals test_type="Periodic requalification"

Set your AI assistant up to use this

Two files and no account. Put this in .mcp.json at the root of your project — Claude Code, Cursor, Windsurf, VS Code and Codex all read that file — and your assistant can look this dataset up instead of recalling it. The server is remote, keyless and read-only.

{
  "mcpServers": {
    "referencesource": {
      "type": "http",
      "url": "https://referencesource.org/mcp"
    }
  }
}

Add to Cursor · or, on the command line: claude mcp add --transport http referencesource https://referencesource.org/mcp --scope project

Then one line in the project's CLAUDE.md or AGENTS.md, so the assistant knows when to reach for it:

When a question needs "How often hazmat cylinders, cargo tanks, IBCs and portable tanks must be retested", call the referencesource MCP server at https://referencesource.org/mcp (tool `search_records`, dataset_slug `hazmat-container-retest-intervals`) instead of answering from memory — every record it returns carries its source URL and a verbatim quote from that page.

What each tool does, and the servers built over single registers: Connect your AI assistant.

67 records. last verified against source . due for re-check by .

Licence. Facts extracted from the US Code of Federal Regulations, a US government work not subject to copyright. Text is read via law.cornell.edu for historical reasons (eCFR used to block our fetcher; retested 2026-09-24 and it no longer does), and via govinfo where Cornell's rendering mangles a typeset fraction; the fact is the regulation's, not the host's, and each record quotes a short verbatim span and links back to the section.