DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4E · External visual inspection · Liquefied petroleum gas that meets the detail requirements limits in Table 1 of ASTM 1835, Standard Specification for Liquefied Petroleum (LP) Gases

For DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4E, test or inspection is External visual inspection; condition or service qualifier is Liquefied petroleum gas that meets the detail requirements limits in Table 1 of ASTM 1835, Standard Specification for Liquefied Petroleum (LP) Gases; interval is at five-year intervals after the first inspection; regulation section is 49 CFR § 180.209, recorded from its source on 2026-10-05.

Container specification
DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4E verified
Test or inspection
External visual inspection our reading
Interval
at five-year intervals after the first inspection verified
Condition or service qualifier
Liquefied petroleum gas that meets the detail requirements limits in Table 1 of ASTM 1835, Standard Specification for Liquefied Petroleum (LP) Gases verified
Regulation section
49 CFR § 180.209
Sourcelaw.cornell.edu
Verified
Review by
DatasetHow often hazmat cylinders, cargo tanks, IBCs and portable tanks must be retested

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

What the source says

DOT 3A, DOT 3AA, DOT 3A480X, DOT 3B, DOT 4B, DOT 4BA, DOT 4BW, DOT 4E | Liquefied petroleum gas that meets the detail requirements limits in Table 1 of ASTM 1835, Standard Specification for Liquefied Petroleum (LP) Gases (incorporated by reference; see § 171.7 of this subchapter) or an equivalent standard containing the same limits.

— law.cornell.edu, retrieved 2026-10-05

Where each value comes from

The value above is stated away from the sentence quoted with the answer, so the passage that states it is shown here too.

Interval

When this inspection is used instead of hydrostatic testing, subsequent inspections are required at five-year intervals after the first inspection.

— all from law.cornell.edu, retrieved 2026-10-05