Specification 60 portable tank

For Specification 60 portable tank, test or inspection is periodic inspection and test; interval is at the end of the first 4-year period after the original test; at least once every 2 years thereafter up to a total of 12 years of service; and at least once annually thereafter; condition or service qualifier is Retesting is not required on a rubber-lined tank except before each relining; regulation section is 49 CFR § 180.605, recorded from its source on 2026-08-10.

Container specification
Specification 60 portable tank verified
Test or inspection
periodic inspection and test our reading
Interval
at the end of the first 4-year period after the original test; at least once every 2 years thereafter up to a total of 12 years of service; and at least once annually thereafter verified
Condition or service qualifier
Retesting is not required on a rubber-lined tank except before each relining verified
Regulation section
49 CFR § 180.605 verified
Sourcelaw.cornell.edu
Verified
Review by
DatasetHow often hazmat cylinders, cargo tanks, IBCs and portable tanks must be retested

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

What the source says

(4) Each Specification 60 portable tank must be given a periodic inspection and test at the end of the first 4-year period after the original test; at least once every 2 years thereafter up to a total of 12 years of service; and at least once annually thereafter. Retesting is not required on a rubber-lined tank except before each relining.