IM or UN portable tank · initial inspection and test

For IM or UN portable tank, test or inspection is initial inspection and test; interval is before being placed into service; regulation section is 49 CFR § 180.605, recorded from its source on 2026-08-10; source re-checked 2026-09-30.

Container specification
IM or UN portable tank verified
Test or inspection
initial inspection and test our reading
Interval
before being placed into service verified
Regulation section
49 CFR § 180.605
Sourcelaw.cornell.edu
Verified
Review by
DatasetHow often hazmat cylinders, cargo tanks, IBCs and portable tanks must be retested

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

What the source says

Each IM or UN portable tank must be given an initial inspection and test before being placed into service, a periodic inspection and test at least once every 5 years, and an intermediate periodic inspection and test at least every 2.5 years following the initial inspection and the last 5 year periodic inspection and test.