at least two brake applications after the warning device has operated (or gauge shows an unsafe reading). · 1.1.3 · (a) · EU Directive 2014/45/EU Annex I
What is the category for at least two brake applications after the warning device has operated (or gauge shows an unsafe reading). · 1.1.3 · (a) · EU Directive 2014/45/EU Annex I?
For at least two brake applications after the warning device has operated (or gauge shows an unsafe reading)., inspection item number is 1.1.3; defect reference is (a); authority is EU Directive 2014/45/EU Annex I; category is Dangerous; inspection item is Vacuum pump or compressor and reservoirs, recorded from its source on 2026-08-06; source re-checked 2026-10-11.
(a) | Insufficient pressure/vacuum to give assistance for at least four brake applications after the warning device has operated (or gauge shows an unsafe reading); at least two brake applications after the warning device has operated (or gauge shows an unsafe reading). | | | X | X
— eur-lex.europa.eu, retrieved 2026-08-06
- Defect
- at least two brake applications after the warning device has operated (or gauge shows an unsafe reading). verified
- Category
- Dangerous
- Inspection item number
- 1.1.3
- Defect reference
- (a) verified
- Inspection item
- Vacuum pump or compressor and reservoirs
- Authority
- EU Directive 2014/45/EU Annex I our reading
Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.
Source