Reference Source

Texas

For Texas, governing body is Texas Department of Licensing and Regulation (TDLR), Compliance Division/Boiler Program; statute citation is Boiler Law, Texas Health and Safety Code, Chapter 755. Administrative Rules, 16 Texas Administrative Code, Chapter 65; power boiler inspection interval is annual certificate inspection and an annual external inspection; low-pressure boiler inspection interval is certificate inspection biennially; accepted inspector types is Inspections of boilers made by authorized inspectors employed by accredited authorized inspection agencies and commissioned by the department are required in lieu of inspections made by a deputy boiler inspector, recorded from its source on 2026-08-05.

State
Texas unconfirmed
Governing body
Texas Department of Licensing and Regulation (TDLR), Compliance Division/Boiler Program unconfirmed
Statute citation
Boiler Law, Texas Health and Safety Code, Chapter 755. Administrative Rules, 16 Texas Administrative Code, Chapter 65. unconfirmed
Power boiler inspection interval
annual certificate inspection and an annual external inspection
Low-pressure boiler inspection interval
certificate inspection biennially
Accepted inspector types
Inspections of boilers made by authorized inspectors employed by accredited authorized inspection agencies and commissioned by the department are required in lieu of inspections made by a deputy boiler inspector. unconfirmed
Exemptions
boilers owned or operated by the federal government; manually fired miniature boilers constructed or maintained for locomotives, boats, tractors, or stationary engines only as a hobby; boilers designed for operation only at atmospheric pressure; steam cookers; Heating boilers used to heat buildings exclusively for residential use and having accommodations for not more than four families unconfirmed
Sourcenationalboard.org
Verified2026-08-05
Review by2027-08-05
DatasetUS boiler and pressure vessel inspection requirements by state

Values marked unconfirmed are shown, but we could not tie them to the quote below: Accepted inspector types, Exemptions, Governing body, State, Statute citation. Read the quote and judge them yourself.

What the source says

Power boilers, unfired steam boilers, and steam collection or liberation drums of process steam generators must receive an annual certificate inspection and an annual external inspection. Steam-heating boilers and hot-water heating boilers must receive a certificate inspection biennially. Hot-water supply boilers and potable water heaters must receive a certificate inspection triennially.

nationalboard.org, retrieved 2026-08-05

Source

Last verified against source: 2026-08-05. Scheduled for re-check by: 2027-08-05. This page as Markdown · OKF bundle · full dataset as JSON.