For powerline-clearance-uninsulated-over-50-kv, paragraph citation is 1926.451(f)(6); type of requirement is minimum clearance from uninsulated power lines; value (imperial) is 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv; applies to is More than 50 kv; regulation section heading is Use, recorded from its source on 2026-08-31; source re-checked 2026-09-14.
Uninsulated lines voltage | Minimum distance | Alternatives | Less than 50 kv | 10 feet (3.1 m) | | More than 50 kv | 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv | 2 times the length of the line insulator, but never less than 10 feet (3.1 m). |
— ecfr.gov, retrieved 2026-08-31
- Requirement ID
- powerline-clearance-uninsulated-over-50-kv our reading
- Paragraph citation
- 1926.451(f)(6) our reading
- Type of requirement
- minimum clearance from uninsulated power lines our reading
- Value (imperial)
- 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv verified
- Applies to
- More than 50 kv verified
- Regulation section heading
- Use verified
Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.
Where each value comes from
The value above is stated away from the sentence quoted with the answer, so the passage that states it is shown here too.
Regulation section heading
(f) Use.
— all from ecfr.gov, retrieved 2026-08-31
Source
- ecfr.govhttps://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451