# powerline-clearance-uninsulated-over-50-kv — Every numeric dimensional tolerance and safety factor in OSHA's scaffold general requirements (29 CFR 1926.451) For powerline-clearance-uninsulated-over-50-kv, paragraph citation is 1926.451(f)(6); type of requirement is minimum clearance from uninsulated power lines; value (imperial) is 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv; applies to is More than 50 kv; regulation section heading is Use, recorded from its source on 2026-08-31; source re-checked 2026-09-14. - **Requirement ID:** powerline-clearance-uninsulated-over-50-kv _(our reading, not quoted from the source)_ - **Paragraph citation:** 1926.451(f)(6) _(our reading, not quoted from the source)_ - **Type of requirement:** minimum clearance from uninsulated power lines _(our reading, not quoted from the source)_ - **Value (imperial):** 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv _(verified: appears in the quote below)_ - **Applies to:** More than 50 kv _(verified: appears in the quote below)_ - **Regulation section heading:** Use _(verified: appears in its own passage below)_ ## What the source says > Uninsulated lines voltage | Minimum distance | Alternatives | Less than 50 kv | 10 feet (3.1 m) | | More than 50 kv | 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv | 2 times the length of the line insulator, but never less than 10 feet (3.1 m). | ## Where each value comes from This source states these in separate places, so each value is shown with the passage that states it. ### Regulation section heading > (f) Use. ## Source - https://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451 Last verified: 2026-09-14. Review by: 2027-08-31. Part of [Every numeric dimensional tolerance and safety factor in OSHA's scaffold general requirements (29 CFR 1926.451)](https://referencesource.org/osha-scaffold-dimensional-tolerances/).