Controlled Decking Zone (CDZ) · 1926.760 Fall protection
What is the hazard situation for Controlled Decking Zone (CDZ) · 1926.760 Fall protection?
For Controlled Decking Zone (CDZ) · 1926.760 Fall protection, hazard situation is Controlled Decking Zone (CDZ); standard is 1926.760 Fall protection; trigger height is over 15 and up to 30 feet above a lower level; required protection once triggered is Each employee working at the leading edge in a CDZ shall be protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever is less; subpart is Subpart R —Steel Erection, recorded from its source on 2026-08-25; source re-checked 2026-09-14.
(c) Controlled Decking Zone (CDZ). A controlled decking zone may be established in that area of the structure over 15 and up to 30 feet above a lower level where metal decking is initially being installed and forms the leading edge of a work area. In each CDZ, the following shall apply: (1) Each employee working at the leading edge in a CDZ shall be protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever is less. (2) Access to a CDZ shall be limited to only those employees engaged in leading edge work.
— ecfr.gov, retrieved 2026-08-25
- Hazard situation
- Controlled Decking Zone (CDZ) verified
- Standard
- 1926.760 Fall protection verified
- Trigger height
- over 15 and up to 30 feet above a lower level verified
- Required protection once triggered
- Each employee working at the leading edge in a CDZ shall be protected from fall hazards of more than two stories or 30 feet (9.1 m), whichever is less verified
- Subpart
- Subpart R —Steel Erection verified
- CFR paragraph
- 29 CFR 1926.760(c) our reading