Connectors · 1926.760 Fall protection

What is the hazard situation for Connectors · 1926.760 Fall protection?

For Connectors · 1926.760 Fall protection, hazard situation is Connectors; standard is 1926.760 Fall protection; trigger height is more than two stories or 30 feet (9.1 m) above a lower level, whichever is less; required protection once triggered is at heights over 15 and up to 30 feet above a lower level, with a personal fall arrest system, positioning device system or fall restraint system and wear the equipment necessary to be able to be tied off; subpart is Subpart R —Steel Erection, recorded from its source on 2026-08-25; source re-checked 2026-09-14.

(b) Connectors. Each connector shall: (1) Be protected in accordance with <https://www.ecfr.gov/current/title-29/section-1926.760#p-1926.760(a)(1)> paragraph (a)(1) of this section from fall hazards of more than two stories or 30 feet (9.1 m) above a lower level, whichever is less; (2) Have completed connector training in accordance with <https://www.ecfr.gov/current/title-29/section-1926.761> § 1926.761 ; and (3) Be provided, at heights over 15 and up to 30 feet above a lower level, with a personal fall arrest system, positioning device system or fall restraint system and wear the equipment necessary to be able to be tied off; or be provided with other means of protection from fall hazards in accordance with <https://www.ecfr.gov/current/title-29/section-1926.760#p-1926.760(a)(1)> paragraph (a)(1) of this section.

ecfr.gov, retrieved 2026-08-25

Hazard situation
Connectors verified
Standard
1926.760 Fall protection verified
Trigger height
more than two stories or 30 feet (9.1 m) above a lower level, whichever is less verified
Required protection once triggered
at heights over 15 and up to 30 feet above a lower level, with a personal fall arrest system, positioning device system or fall restraint system and wear the equipment necessary to be able to be tied off verified
Subpart
Subpart R —Steel Erection verified
CFR paragraph
29 CFR 1926.760(b) our reading
Sourceecfr.gov
Verified
Review by
DatasetOSHA fall protection trigger height by standard