Florida
What is the governing body for Florida?
For Florida, governing body is Bureau of Fire Prevention, Boiler Safety Section, Division of the State Fire Marshal; statute citation is Florida Statutes, Title 33. Regulations of Trade, Commerce, Investments and Solicitations, Chapter 554. Boiler Safety , Sections 101.1 through 115.0; power boiler inspection interval is certificate inspection annually; external inspection while under pressure; internal inspection if the construction so permits; low-pressure boiler inspection interval is certificate inspection biennially; internal inspection if the construction so permits; accepted inspector types is Insurance companies required to do inservice inspections of all insured boilers in areas of public assembly; upon filing report of satisfactory inspection, boiler exempt from inspection by the Boiler Safety Program, recorded from its source on 2026-08-05.
Power boilers and high-temperature water boilers: Certificate inspection annually; External inspection while under pressure; Internal inspection if the construction so permits. Low-pressure steam or vapor heating boilers: Certificate inspection biennially; Internal inspection if the construction so permits. Hot-water heating and hot-water supply boilers: Certificate inspection biennially; Internal inspection every four years if the construction so permits.
— nationalboard.org, retrieved 2026-08-05
- State
- Florida
- Governing body
- Bureau of Fire Prevention, Boiler Safety Section, Division of the State Fire Marshal
- Statute citation
- Florida Statutes, Title 33. Regulations of Trade, Commerce, Investments and Solicitations, Chapter 554. Boiler Safety , Sections 101.1 through 115.0.
- Power boiler inspection interval
- certificate inspection annually; external inspection while under pressure; internal inspection if the construction so permits verified
- Low-pressure boiler inspection interval
- certificate inspection biennially; internal inspection if the construction so permits verified
- Accepted inspector types
- Insurance companies required to do inservice inspections of all insured boilers in areas of public assembly; upon filing report of satisfactory inspection, boiler exempt from inspection by the Boiler Safety Program
- Exemptions
- Boilers and lined hot-water heaters under the control of the federal government; HLW hot-water supply boilers or lined storage water heaters directly fired with oil, gas, electricity, or solar energy not exceeding 400,000 BTU per hour, 210°F, 120 gallons
Source
- nationalboard.orghttps://www.nationalboard.org/PrintAllSynopsis.aspx?Jurisdiction=Select