NIST SP 800-53 Rev 5.2.0 AU-5(4) — Shutdown on Failure
What is the what it requires, verbatim for NIST SP 800-53 Rev 5.2.0 AU-5(4) — Shutdown on Failure?
For NIST SP 800-53 Rev 5.2.0 AU-5(4), what it requires, verbatim is Invoke a {{ insert: param, au-05.04_odp.01 }} in the event of {{ insert: param, au-05.04_odp.02 }} , unless an alternate audit logging capability exists; control title is Shutdown on Failure; family is Audit and Accountability; organization-defined values is full system shutdown or partial system shutdown or degraded operational mode with limited mission or business functionality available; audit logging failures, recorded from its source on 2026-11-15.
Invoke a {{ insert: param, au-05.04_odp.01 }} in the event of {{ insert: param, au-05.04_odp.02 }} , unless an alternate audit logging capability exists.
— raw.githubusercontent.com, retrieved 2026-11-15
- Citation
- AU-5(4) our reading
- Framework
- NIST SP 800-53 Rev 5.2.0 our reading
- Control
- AU-5(4)
- Control title
- Shutdown on Failure verified
- Family
- Audit and Accountability verified
- What it requires, verbatim
- Invoke a {{ insert: param, au-05.04_odp.01 }} in the event of {{ insert: param, au-05.04_odp.02 }} , unless an alternate audit logging capability exists. verified
- What it requires, with its parameters named
- Invoke a [Selection (one or more): full system shutdown; partial system shutdown; degraded operational mode with limited mission or business functionality available] in the event of [Assignment: organization-defined audit logging failures] , unless an alternate audit logging capability exists. our reading
- Organization-defined values
- full system shutdown or partial system shutdown or degraded operational mode with limited mission or business functionality available; audit logging failures our reading
Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.
Cite as: NIST SP 800-53 Rev 5.2.0 AU-5(4) — Shutdown on Failure (Security and compliance controls, one provision at a time: NIST SP 800-53 and the HIPAA Security Rule in their own words), referencesource.org/security-compliance-controls/au-5-4/, checked 2026-11-15.
Where each value comes from
This source states these in separate places, so each value is shown with the passage that states it.
Framework
"title": "Electronic (OSCAL) Version of NIST SP 800-53 Rev 5.2.0 Controls and SP 800-53A Rev 5.2.0 Assessment Procedures",
Control and Control title
"id": "au-5.4", "class": "SP800-53-enhancement", "title": "Shutdown on Failure",
Family
"id": "au", "class": "family", "title": "Audit and Accountability",
— all from raw.githubusercontent.com, retrieved 2026-11-15
Source
- raw.githubusercontent.comhttps://raw.githubusercontent.com/usnistgov/oscal-content/main/nist.gov/SP800-53/rev5/json/NIST_SP-800-53_rev5_catalog.json