Reference Source

Certification marks and hazardous-area classifications: cross-market equivalences

Which product-safety certification mark applies in which market, who administers it and under what law (CE, UL, CSA, CCC, PSE, KC, BSMI, RCM, EAC, NOM, INMETRO and others), and how the two hazardous-area classification systems map onto each other: NEC Class/Division designations against IEC/ATEX Zone designations, gas group cross-references (NEC Group A-D against IEC IIA-IIC), temperature-class mappings, and the protection-concept codes (Ex d, AEx e, intrinsic safety) with the US, Canadian and IEC standards behind each. Answers 'is a CB certificate accepted in the US', 'what is the ATEX equivalent of Class I Division 2', and 'which mark is compulsory in China' — questions where the honest answer is often that there is no direct equivalent, and saying so is the value.

Records200
Sources12
Verified
Review by
LicenceFactual compilation with source citations. Facts about which mark applies where and how classification systems map are taken with short attributed quotes linking back to the published guide or page. No standard text is reproduced.

9 records where two or more sources state different values. Both sides are reproduced on the record page, each with its own source and quote.

The data

DesignationStated equivalentApplies toGoverning standard / lawMarket / systemAdministered byMandatory / voluntaryMeaning
AIICAcetylene
AEx maDZone 20ISA 61241-18
S MarkArgentinaIRAMmandatory in Argentina
II 1DDaZone 20, 21 & 22ATEX
II 1GGaZone 0, 1 & 2ATEX
II 2DDbZone 21 & 22ATEX
II 2GGbZone 1 & 2ATEX
II 3DDcZone 22 onlyATEX
II 3GGcZone 2 onlyATEX
RCMAustraliaStandards Australiaconsolidates the previously separate C-Tick, A-Tick and RCM marks, effective from March 2013
BIIC (partially IIB+H₂)Hydrogen, butadiene
INMETRO Markmedical electrical equipment, ballasts and equipment used in hazardous locationsBrazilmandatory in Brazil
CIIBEthylene, ethyl ether
(DIP) A21Division 1Class IICSA E61241-1-1CA
ExDivision 1 & 2Class ICSA 60079-0CA
Ex dZone 1Class ICSA 60079-1CA
Ex eZone 1Class ICSA E60079-7CA
EX iaZone 0Class ICSA E60079-11CA
Ex ibZone 1Class ICSA E60079-11CA
Ex mZone 1Class ICSA E60079-18CA
EX nAZone 2Class ICSA E60079-15CA
Ex nCZone 2Class ICSA E60079-15CA
Ex nLZone 2Class ICSA E60079-15CA
Ex nRZone 2Class ICSA E60079-15CA
EX oZone 1Class ICSA E60079-6CA
Ex pxZone 1Class ICSA E60079-2CA
Ex pyZone 1Class ICSA E60079-2CA
Ex pzZone 2Class ICSA E60079-2CA
Ex qZone 1Class ICSA E60079-5CA
(IS)sources differDivision 1Class IC22.2 No. 157CA
(NI)Division 2Class IC22.2 No. 213CA
(PX)Division 1Class IINFPA 496CA
(PY)Division 1Class IINFPA 496CA
(PZ)Division 2Class IINFPA 496CA
Type YDivision 1Class INFPA 496CA
Type ZDivision 2Class INFPA 496CAPressurized
(XP)Division 1Class IC22.2 No. 30CA
CAN/CSA-C22.2 No. 60335-1IEC 60335-1Canada
CSA MarkCanadaCanadian Standards Associationidentify products acceptable in either Canada (C suffix letter) and/or the USA (US suffix)
CB SchemeIECEEthe world’s first international system for the mutual acceptance of product safety test reports and certificates for electrical and electronic equipment, devices, and components
CE MarkingDecision 768/2008a manufacturer’s declaration that a product meets the applicable health, safety, and environmental requirements outlined in the appropriate European product legislation and has undergone the relevant conformity assessment procedure
Certification Body (CB) schemeallows manufacturers who have been issued a CB test certificate by one National Certification Body (NCB) to obtain certification marks from other participating NCBs
CCC MarkChinacompulsory for any product used for commercial purposes in Chinaindicates compliance with Chinese laws and regulations
Class IIZone 20/21/22NEC separates dust into Class II (Groups E, F, G); IEC integrates dust into the same zone framework (Zone 20/21/22) with dust groups IIIA, IIIB, IIIC
Class IIINEC Class III (fibers/flyings) has no IEC equivalent
DIIAMethane, propane, gasoline
(DIP) A22Division 2CSA E61241-1-1
Division 1sources differZone 1 (+ Zone 0)Explosive atmosphere likely during normal operation (10–1000 hrs/yr)
Division 2sources differZone 2Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)
Dust-ignition-proofEx t (Dust protection by enclosure)IEC 60079-31Prevent dust ingress and limit surface temperature
CE markingEUcompulsory for most products covered by the New Approach Directives
EMC DirectiveWired-only industrial sensors with no radio transmitter2014/30/EUEU
EN 300 3282.4 GHz Wi-Fi and Bluetooth devicesEUthe primary standard for Article 3.2 radio spectrum compliance for 2.4 GHz Wi-Fi and Bluetooth devices
EN 62368-1EN 60950-1EUcovers Article 3.1(a) audio/video and IT equipment safety
Low Voltage Directivemains-powered above 50V AC or 75V DC2014/35/EUEU
LVDelectrical equipment operating between 50–1000V AC2014/35/EUEUSafety requirements for electrical equipment operating between 50–1000V AC
Machinery Directivemachines and mechanical equipment2006/42/ECEUSafety requirements for machines and mechanical equipment
MDRmedical devices2017/745EUMedical device regulation with strict clinical and documentation requirements
Radio Equipment Directive (RED)Directive 2014/53/EUEUthe governing framework for any radio-transmitting device placed on the EU market
REDRadio equipment including Wi-Fi, Bluetooth, and cellular2014/53/EUEURadio equipment including Wi-Fi, Bluetooth, and cellular
A-deviationEuropeInformation that the provisions of an EN are in conflict with national regulation shall be included in an Annex to the European Standard, called A-deviation
CE markingEU-Regulations or EU-DirectivesEuropeindicates that a product is declared by the manufacturer as being in conformity with European Union harmonization legislation
EN 60335-1IEC 60335-1Europedefines how appliances may comply with European directives, such as the low voltage directive
ENEC MarkEuropethe mark used to denote compliance with the European Norm (EN) standards for all electrical product sectors
EU Declaration of Conformity (EU-DoC)ISO/IEC 17050-1 and -2Europethe EU legislation imposes an obligation on the manufacturer to draw up and sign a legally binding EU Declaration of Conformity (EU-DoC) before placing the product on the market
European Standard (EN)EuropeCENELECA-deviations do not release CENELEC members from their obligation to implement the relevant European Standard
Notified BodyEuropeFor some categories of products, involvement of a third-party conformity assessment body is necessary
CE MarkEuropean Economic AreaSimple CE marking is allowed under a self-certification process if the risk level of a product is considered minimala manufacturer's declaration that the product meets these requirements
Ex d / da / db / dcEN/IEC 60079-1Flameproof
Ex e / eb / ecEN/IEC 60079-7Increased Safety
Ex i / ia / ib / icEN/IEC 60079-11Intrinsic Safety
Ex m / ma / mb / mcEN/IEC 60079-18
Ex nA / nC / nLEN/IEC 60079-15Non Sparking
Ex o / ob / ocEN/IEC 60079-6Oil Immersion
Ex op is / op sh / op prEN/IEC 60079-28
Ex p / pxb / pyb / pzcIEC 60079-2Purge/Pressurised
Ex q / qb / qcEN/IEC 60079-5Quartz/Sand Filled
Explosion-proof (XP)Ex d (Flameproof)IEC 60079-1Contain the explosion inside the enclosure
DIN EN 60950-1IEC 60950-1Germany
DIN MarkGermanyTUV Rheinlandcertifying component compliance with DIN, EN, IEC and ISO product safety standards
GS MarkGPSG = Geräte- und ProduktisicherheitgesetzGermanyTUV Rheinland
VDE MarkGermanyVDE Testing and Certification Instituteindicates conformity with the VDE standards, European or internationally harmonized standards and confirms compliance with protective requirements of the applicable EC Directive(s)
Group AIICAcetylene
Group BIICHydrogen
Group CIIBEthylene
Group Dsources differIIAPropane
Group ECombustible Metal Dusts
Group FClass II
Hermetically sealedEx nC / Ex mIEC 60079-15 / -18Seal ignition source from atmosphere
Ex dIEC 60079 seriesIEC / ATEXFlameproof enclosure
Ex eIEC 60079 seriesIEC / ATEXIncreased safety
Ex iIEC 60079 seriesIEC / ATEXIntrinsic safety
Ex mIEC 60079 seriesIEC / ATEXEncapsulation
Ex pIEC 60079 seriesIEC / ATEXPressurization
IIAPropaneIEC / ATEX
IIBEthyleneIEC / ATEX
IICHydrogen / acetyleneIEC / ATEX
T1450°CIEC / ATEX
T2300°CIEC / ATEX
T3200°CIEC / ATEX
T4135°CIEC / ATEX
T5100°CIEC / ATEX
T685°CIEC / ATEX
Zone 0IEC / ATEXExplosive atmosphere present continuously or for long periods
Zone 1IEC / ATEXExplosive atmosphere likely during normal operation
Zone 2IEC / ATEXExplosive atmosphere unlikely in normal operation, only short duration eg. accidental leakage
Zone 20IEC / ATEXCombustible dust present continuously
Zone 21IEC / ATEXDust likely during normal operation
Zone 22IEC / ATEXDust unlikely except briefly
IEC 62368-1IECa unified replacement for the previous two standards
IECExIECEx certificates are increasingly accepted as the basis for national approvals in both ATEX and non-ATEX countries
Supplier's Declaration of Conformity (SDoC)ISO/IEC 17050-1:2004Internationala type of conformity assessment that allows a supplier to make a first-party attestation that an object of conformity fulfils specified requirements
Intrinsically Safe (IS)Ex i (Ex ia, Ex ib)IEC 60079-11Limit energy below ignition threshold
PSE MarkElectrical Appliance and Material Safety Law (DENAN)Japan
KC MarkElectrical Appliances and Materials Safety Control LawKoreaAgency for Technology and Standards (KATS)
SIRIMElectricity Supply Act 1990MalaysiaSIRIM QAS International
NMX-J-521/1-ANCEIEC 60335-1Mexico
NOM Markhousehold electrical appliances, IT, AV and similar equipmentMexicoANCE
Zone 0NEC 500The most hazardous environments (continuous explosive atmosphere) have no direct NEC 500 equivalent
AIICAcetyleneNEC
Division 1sources differZone 0 / Zone 20NEC and CEC
Division 2Zone 2 / Zone 22NEC and CEC
BIICHydrogenNEC
CIIBEthyleneNEC
Class INECFlammable gases and vapors
Class I Division 1sources differZone 0NECContinuous hazard
Class I Division 2Zone 2NECOccasional hazard
Class IINECCombustible dust
Class IIINECIgnitable fibers
DIIAPropaneNEC
Division 1NECHazard present during normal operation
Division 2NECHazard present only under abnormal conditions
EMetal dustNEC
FCarbon dustNEC
GGrain / flour dustNEC
Supplier's declaration of conformityElectricity (Safety) Regulations 2010New Zealandrequired before placing on the market any low voltage or extra-low voltage fittings or appliances that have been declared as medium risk by the regulator
Non-incendiveEx nA / Ex ecIEC 60079-15 / -7Normal operation cannot cause ignition
Nemko MarkNorwayNemkosignifies that Nemko has tested or certified the product according to national standards in Norway
Purged/PressurizedEx p (Ex px, Ex py, Ex pz)IEC 60079-2Maintain positive pressure with inert gas
EACRussiaused to indicate products that meet all of the technical requirements of the Eurasian Customs Union
SAFETY MarkSingaporeProductivity and Standards Board (PSB)requires all controlled goods to be individually marked
T1T1450º C (842ºF)
T2300º C (572ºF)
T2A280º C (536ºF)
T2BT2260º C (500ºF)
T2C230º C (446ºF)
T2D215º C (419ºF)
T3200º C (392ºF)
T3A180º C (356ºF)
T3B165º C (329ºF)
T3C160º C (320ºF)
T4135º C (275ºF)
T4A120º C (248ºF)
T5T5100º C (212ºF)
T6T685º C (185ºF)
ta / tb / tcEN/IEC 60079-31Enclosure
BSMIITE and audio/ video productsTaiwanBureau of Standards, Metrology and Inspection
BS EN IEC 60335IEC 60335Safety rules for household appliancesUKIdentical adoption ensures UK manufacturers meet both European and international safety expectations
BS EN ISO 14001:2015ISO 14001Environmental managementUKIdentical adoption ensures UK businesses comply with international and European requirements
BS EN ISO 9001ISO 9001UKif you're compliant with BS EN ISO 9001 in the UK, it's equal to compliance with both ISO 9001 internationally and EN ISO 9001 in Europe
BSI KitemarkUKBritish Standards Institution (BSI)voluntary certification mark
UL MarkUnderwriters Laboratoriestested and determined that a product meets UL specified product safety requirements
UL 60335-1IEC 60335-1United States
AEx dZone 1Class IISA 60079-1USFlame Proof
AEx eZone 1Class IISA 60079-7USIncreased Safety
AEx iaZone 0Class IISA 60079-11USIntrinsic Safety
AEx iaDZone 20ISA 61241-11US
AEx ibZone 1Class IISA 60079-11US
AEx ibDZone 21ISA 61241-11US
AEx mZone 1Class IISA 60079-18US
AEx maZone 0Class IISA 60079-18US
AEx mbZone 1Class IISA 60079-18US
AEx mbDZone 21ISA 61241-18US
AEx nAZone 2Class IISA 60079-15US
AEx nCsources differZone 2Class IISA 60079-15USEnclosed Break
AEx nRZone 2Class IISA 60079-15US
AEx oZone 1Class IISA 60079-6US
AEx pDZone 21ISA 61241-2US
AEx pxZone 1Class IISA 60079-2US
AEx pyZone 1Class IISA 60079-2US
AEx pzZone 2Class IISA 60079-2US
AEx qZone 1Class IISA 60079-5USPower Filled
AEx tDZone 21ISA 60079-31US
ATEX/IECEx certificationUSnot recognized in the US or Canada
Declaration of ConformityUSFederal Communications Commission (FCC)the U.S. Federal Communications Commission (FCC) has adopted a rule that permits recognition of SDoC (also sometimes called Self Declaration of Conformity) for certain information technology devices
(DIP)Division 1Class IIUL 1203US
ExZone 20, 21, 22ISA 60079-0US
FCC Certification47 CFR § 15.201USTelecommunications Certification Body (TCB)non-negotiable for anything with a wireless stackany intentional radiator — a device designed to transmit RF for communication purposes, including Wi-Fi, Bluetooth, LTE, Zigbee, and similar protocols — must obtain FCC Certification through an accredited Telecommunications Certification Body (TCB) before it can be marketed in the US
(IS)sources differDivision 1Class IUL 913 / FM 3610US
NEC 505USNEC 505 (Zone-based) is accepted in the US and provides easier mapping from IEC zones
(NI)sources differDivision 2Class IISA 12.12.01/FM 3611USNon-Incendive
(PX)Division 1Class IINFPA 496 (FM 3620)US
(PZ)Division 2Class IINFPA 496 (FM 3620)US
Supplier's Declaration of Conformity (SDoC)unintentional radiatorUSFederal Communications Commission (FCC)a self-certification path under which the manufacturer tests to FCC limits internally and publishes a declaration
Type XDivision 1Class INFPA 496 (FM 3620)US
Type YDivision 1Class INFPA 496 (FM 3620)US
Type ZDivision 2Class INFPA 496 (FM 3620)US
UL standardUSUL Standards & EngagementStandards are voluntary but can become mandatory and legally binding if referenced in adopted code, written into law, or required by a government agency like the U.S. Consumer Product Safety Commissiona published set of best practices for testing and evaluating the safety, security, and sustainability of a product or system
(XP)Division 1Class IUL 1203USExplosion Proof
Zone 01G

Where this came from

Every record above links the page it was taken from and quotes the sentence that states it. These are the 12 sources this dataset was assembled from.

Machine-readable

200 records. last verified against source . due for re-check by .

Licence. Factual compilation with source citations. Facts about which mark applies where and how classification systems map are taken with short attributed quotes linking back to the published guide or page. No standard text is reproduced.