prefabricated-access-frame-rest-platform-interval
What is the paragraph citation for prefabricated-access-frame-rest-platform-interval?
For prefabricated-access-frame-rest-platform-interval, paragraph citation is 1926.451(e)(6)(v); type of requirement is maximum vertical interval; value (imperial) is 35-foot; value (metric) is 10.7 m; applies to is all supported scaffolds more than 35 feet (10.7 m) high, recorded from its source on 2026-08-31; source re-checked 2026-09-14.
(v) Be provided with rest platforms at 35-foot (10.7 m) maximum vertical intervals on all supported scaffolds more than 35 feet (10.7 m) high; and
— ecfr.gov, retrieved 2026-08-31
- Requirement ID
- prefabricated-access-frame-rest-platform-interval our reading
- Paragraph citation
- 1926.451(e)(6)(v) our reading
- Type of requirement
- maximum vertical interval our reading
- Value (imperial)
- 35-foot verified
- Value (metric)
- 10.7 m verified
- Applies to
- all supported scaffolds more than 35 feet (10.7 m) high verified
- Regulation section heading
- Access verified
Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.
Where each value comes from
The value above is stated away from the sentence quoted with the answer, so the passage that states it is shown here too.
Regulation section heading
(e) Access.
— all from ecfr.gov, retrieved 2026-08-31
Source
- ecfr.govhttps://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1926/subpart-L/section-1926.451