powerline-clearance-insulated-300-volts-to-50-kv
What is the paragraph citation for powerline-clearance-insulated-300-volts-to-50-kv?
For powerline-clearance-insulated-300-volts-to-50-kv, paragraph citation is 1926.451(f)(6); type of requirement is minimum clearance from insulated power lines; value (imperial) is 10 feet; value (metric) is 3.1m; applies to is 300 volts to 50 kv, recorded from its source on 2026-08-31; source re-checked 2026-09-14.
Insulated lines voltage | Minimum distance | Alternatives | Less than 300 volts | 3 feet (0.9 m) | | 300 volts to 50 kv | 10 feet (3.1m) |
— ecfr.gov, retrieved 2026-08-31