Reference Source

max-distance-to-work-face-plastering-lathing

What is the paragraph citation for max-distance-to-work-face-plastering-lathing?

For max-distance-to-work-face-plastering-lathing, paragraph citation is 1926.451(b)(3)(ii); type of requirement is maximum gap; value (imperial) is 18 inches; value (metric) is 46 cm; applies to is plastering and lathing operations, recorded from its source on 2026-08-31; source re-checked 2026-09-14.

(ii) The maximum distance from the face for plastering and lathing operations shall be 18 inches (46 cm).

ecfr.gov, retrieved 2026-08-31

Requirement ID
max-distance-to-work-face-plastering-lathing our reading
Paragraph citation
1926.451(b)(3)(ii) our reading
Type of requirement
maximum gap our reading
Value (imperial)
18 inches verified
Value (metric)
46 cm verified
Applies to
plastering and lathing operations verified
Regulation section heading
Scaffold platform construction verified
Sourceecfr.gov
Verified
Review by
DatasetEvery numeric dimensional tolerance and safety factor in OSHA's scaffold general requirements (29 CFR 1926.451)

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

Where each value comes from

The value above is stated away from the sentence quoted with the answer, so the passage that states it is shown here too.

Regulation section heading

(b) Scaffold platform construction.

— all from ecfr.gov, retrieved 2026-08-31

Source

Last verified against source: . Due for re-check by . This page as Markdown · OKF bundle · full dataset as JSON.