What is the paragraph citation for end-frame-climbing-maximum-vertical-spacing?

For end-frame-climbing-maximum-vertical-spacing, paragraph citation is 1926.451(e)(9)(iii); type of requirement is maximum spacing; value (imperial) is 22 inches; applies to is erecting or dismantling tubular welded frame scaffolds; regulation section heading is Access, recorded from its source on 2026-08-31; source re-checked 2026-09-14.

(iii) When erecting or dismantling tubular welded frame scaffolds, (end) frames, with horizontal members that are parallel, level and are not more than 22 inches apart vertically may be used as climbing devices for access, provided they are erected in a manner that creates a usable ladder and provides good hand hold and foot space.

ecfr.gov, retrieved 2026-08-31

Requirement ID
end-frame-climbing-maximum-vertical-spacing our reading
Paragraph citation
1926.451(e)(9)(iii) our reading
Type of requirement
maximum spacing our reading
Value (imperial)
22 inches verified
Applies to
erecting or dismantling tubular welded frame scaffolds verified
Regulation section heading
Access verified
Sourceecfr.gov
Verified
Review by
DatasetEvery numeric dimensional tolerance and safety factor in OSHA's scaffold general requirements (29 CFR 1926.451)

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

Where each value comes from

The value above is stated away from the sentence quoted with the answer, so the passage that states it is shown here too.

Regulation section heading

(e) Access.

— all from ecfr.gov, retrieved 2026-08-31

Source

Last verified against source: . Due for re-check by . This page as Markdown · OKF bundle · full dataset as JSON.