walkway located within a scaffold · 1926.451 General requirements
What is the hazard situation for walkway located within a scaffold · 1926.451 General requirements?
For walkway located within a scaffold · 1926.451 General requirements, hazard situation is walkway located within a scaffold; standard is 1926.451 General requirements; required protection once triggered is a guardrail system (with minimum 200 pound toprail capacity); subpart is Subpart L —Scaffolds; cfr paragraph is 29 CFR 1926.451(g)(1)(v), recorded from its source on 2026-08-25; source re-checked 2026-09-14.
(v) Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 91⁄2 inches (24.1 cm) of and along at least one side of the walkway.
— ecfr.gov, retrieved 2026-08-25
- Hazard situation
- walkway located within a scaffold verified
- Standard
- 1926.451 General requirements verified
- Required protection once triggered
- a guardrail system (with minimum 200 pound toprail capacity) verified
- Subpart
- Subpart L —Scaffolds verified
- CFR paragraph
- 29 CFR 1926.451(g)(1)(v) our reading