Reference Source

Exhaust gas analysers · Annex XII · O2 fraction, class 0, rated operating conditions

For Exhaust gas analysers, annex is Annex XII; condition is O2 fraction, class 0, rated operating conditions; accuracy class is 0; maximum permissible error is ± 0,1 % vol ± 5 %; scope or member state option is For each of the fractions measured, the maximum error value permitted under rated operating conditions according to point 1.1 of Annex I is the greater of the two values shown in Table 2. Absolute values are expressed in % vol or ppm vol, percentage values are percent of the true value, recorded from its source on 2026-09-01.

Instrument type
Exhaust gas analysers verified
Annex
Annex XII verified
Accuracy class
0 verified
Condition
O2 fraction, class 0, rated operating conditions our reading
Maximum permissible error
± 0,1 % vol ± 5 % verified
Scope or member state option
For each of the fractions measured, the maximum error value permitted under rated operating conditions according to point 1.1 of Annex I is the greater of the two values shown in Table 2. Absolute values are expressed in % vol or ppm vol, percentage values are percent of the true value. verified
Sourceeur-lex.europa.eu
Verified
Review by
DatasetAccuracy classes and maximum permissible errors for trade measuring instruments

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

What the source says

For each of the fractions measured, the maximum error value permitted under rated operating conditions according to point 1.1 of Annex I is the greater of the two values shown in Table 2. Absolute values are expressed in % vol or ppm vol, percentage values are percent of the true value. Table 2 MPEs | Parameter | Class 0 | Class I | CO fraction | ± 0,03 % vol ± 5 % | ± 0,06 % vol ± 5 % | CO2 fraction | ± 0,5 % vol ±5 % | ± 0,5 % vol ± 5 % | HC fraction | ± 10 ppm vol ± 5 % | ± 12 ppm vol ± 5 % | O2 fraction | ± 0,1 % vol ± 5 % | ± 0,1 % vol ± 5 %

— eur-lex.europa.eu, retrieved 2026-09-01

Where each value comes from

This source states these in separate places, so each value is shown with the passage it comes from.

Instrument type

ANNEX XII EXHAUST GAS ANALYSERS (MI-010) The relevant requirements of Annex I, the specific requirements of this Annex and the conformity assessment procedures listed in this Annex, apply to exhaust gas analysers defined below intended for inspection and professional maintenance of motor vehicles in use.

Annex

ANNEX XII EXHAUST GAS ANALYSERS (MI-010)

Accuracy class

The source prints this value inside the passage below but does not name it there. The passage shows where it appears; what ties it to this record is the position on the page, not anything the passage says.

For each of the fractions measured, the maximum error value permitted under rated operating conditions according to point 1.1 of Annex I is the greater of the two values shown in Table 2. Absolute values are expressed in % vol or ppm vol, percentage values are percent of the true value. Table 2 MPEs | Parameter | Class 0

Maximum permissible error

For each of the fractions measured, the maximum error value permitted under rated operating conditions according to point 1.1 of Annex I is the greater of the two values shown in Table 2. Absolute values are expressed in % vol or ppm vol, percentage values are percent of the true value. Table 2 MPEs | Parameter | Class 0 | Class I | CO fraction | ± 0,03 % vol ± 5 % | ± 0,06 % vol ± 5 % | CO2 fraction | ± 0,5 % vol ±5 % | ± 0,5 % vol ± 5 % | HC fraction | ± 10 ppm vol ± 5 % | ± 12 ppm vol ± 5 % | O2 fraction | ± 0,1 % vol ± 5 %

— all from eur-lex.europa.eu, retrieved 2026-09-01

Source

Last verified against source: . Due for re-check by . This page as Markdown · OKF bundle · full dataset as JSON.