Measuring systems for the continuous and dynamic measurement of quantities of liquids other than water · Annex VII · meters (line B of Table 2), quantities ≥ 2 litres, class 1,0

For Measuring systems for the continuous and dynamic measurement of quantities of liquids other than water, annex is Annex VII; condition is meters (line B of Table 2), quantities ≥ 2 litres, class 1,0; accuracy class is 1,0; maximum permissible error is 0,6 %, recorded from its source on 2026-09-01.

Instrument type
Measuring systems for the continuous and dynamic measurement of quantities of liquids other than water verified
Annex
Annex VII verified
Accuracy class
1,0 verified
Condition
meters (line B of Table 2), quantities ≥ 2 litres, class 1,0 our reading
Maximum permissible error
0,6 % verified
Sourceeur-lex.europa.eu
Verified
Review by
DatasetAccuracy classes and maximum permissible errors for trade measuring instruments

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

What the source says

2.1. For quantities equal to or greater than 2 litres the MPE on indications is: Table 2 | Accuracy Class | | 0,3 | 0,5 | 1,0 | 1,5 | 2,5 | Measuring systems (A) | 0,3 % | 0,5 % | 1,0 % | 1,5 % | 2,5 % | Meters (B) | 0,2 % | 0,3 % | 0,6 % | 1,0 % | 1,5 % | 2.2. For quantities less than two litres the MPE on indications is:

— eur-lex.europa.eu, retrieved 2026-09-01

Where each value comes from

This source states these in separate places, so each value is shown with the passage it comes from.

Instrument type

ANNEX VII MEASURING SYSTEMS FOR THE CONTINUOUS AND DYNAMIC MEASUREMENT OF QUANTITIES OF LIQUIDS OTHER THAN WATER (MI-005) The relevant essential requirements of Annex I, the specific requirements of this Annex and the conformity assessment procedures listed in this Annex, apply to measuring systems intended for the continuous and dynamic measurement of quantities (volumes or masses) of liquids other than water.

Annex

ANNEX VII MEASURING SYSTEMS FOR THE CONTINUOUS AND DYNAMIC MEASUREMENT OF QUANTITIES OF LIQUIDS OTHER THAN WATER (MI-005)

Accuracy class

The source prints this value inside the passage below but does not name it there. The passage shows where it appears; what ties it to this record is the position on the page, not anything the passage says.

2.1. For quantities equal to or greater than 2 litres the MPE on indications is: Table 2 | Accuracy Class | | 0,3 | 0,5 | 1,0

Maximum permissible error

2.1. For quantities equal to or greater than 2 litres the MPE on indications is: Table 2 | Accuracy Class | | 0,3 | 0,5 | 1,0 | 1,5 | 2,5 | Measuring systems (A) | 0,3 % | 0,5 % | 1,0 % | 1,5 % | 2,5 % | Meters (B) | 0,2 % | 0,3 % | 0,6 %