Reference Source

Non-automatic weighing instruments · class I, load 200 000 e < m, on initial verification

For Non-automatic weighing instruments, condition is class I, load 200 000 e < m, on initial verification; accuracy class is I; maximum permissible error is ± 1,5 e; scope or member state option is The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1, recorded from its source on 2026-10-13.

Instrument type
Non-automatic weighing instruments verified
Accuracy class
I verified
Condition
class I, load 200 000 e < m, on initial verification our reading
Maximum permissible error
± 1,5 e verified
Scope or member state option
The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1. verified
Sourceeur-lex.europa.eu
Verified
Review by
DatasetAccuracy classes and maximum permissible errors for trade measuring instruments

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

What the source says

Table 3 Maximum permissible errors | Load | Maximum permissible error | Class I | Class II | Class III | Class IIII | 0 ≤ m ≤ 50 000 e | 0 ≤ m ≤ 5 000 e | 0 ≤ m ≤ 500 e | 0 ≤ m ≤ 50 e | ± 0,5 e | 50 000 e < m ≤ 200 000 e | 5 000 e < m ≤ 20 000 e | 500 e < m ≤ 2 000 e | 50 e < m ≤ 200 e | ± 1,0 e | 200 000 e < m | 20 000 e < m ≤ 100 000 e | 2 000 e < m ≤ 10 000 e | 200 e < m ≤ 1 000 e | ± 1,5 e

— eur-lex.europa.eu, retrieved 2026-10-13

Where each value comes from

This source states these in separate places, so each value is shown with the passage it comes from.

Instrument type

1. This Directive shall apply to all non-automatic weighing instruments.

Accuracy class

The source prints this value inside the passage below but does not name it there. The passage shows where it appears; what ties it to this record is the position on the page, not anything the passage says.

Table 3 Maximum permissible errors | Load | Maximum permissible error | Class I

Scope or member state option

The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1.

— all from eur-lex.europa.eu, retrieved 2026-10-13

What oiml.org says

The maximum permissible errors for increasing or decreasing loads are given in Table 6. Table 6 Maximum permissible For loads, m, expressed in verification scale intervals, e errors on initial Class I Class II Class III Class IIII verification ± 0.5 e 0 ≤ m ≤ 50 000 0 ≤ m ≤ 5 000 0 ≤ m ≤ 500 0 ≤ m ≤ 50 ± 1.0 e 50 000 < m ≤ 200 000 5 000 < m ≤ 20 000 500 < m ≤ 2 000 50 < m ≤ 200 ± 1.5 e 200 000 < m 20 000 < m ≤ 100 000 2 000 < m ≤ 10 000 200 < m ≤ 1 000

— oiml.org, retrieved 2026-10-07

Instrument type

This Recommendation specifies the metrological and technical requirements for non-automatic weighing instruments that are subject to official metrological control.

Scope or member state option

The maximum permissible errors in service shall be twice the maximum permissible errors on initial verification (see 8.4.2).

Sources