Non-automatic weighing instruments · class I, load 200 000 e < m, on initial verification
For Non-automatic weighing instruments, condition is class I, load 200 000 e < m, on initial verification; accuracy class is I; maximum permissible error is ± 1,5 e; scope or member state option is The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1, recorded from its source on 2026-10-13.
- Instrument type
- Non-automatic weighing instruments verified
- Accuracy class
- I verified
- Condition
- class I, load 200 000 e < m, on initial verification our reading
- Maximum permissible error
- ± 1,5 e verified
- Scope or member state option
- The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1. verified
Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.
What the source says
Table 3 Maximum permissible errors | Load | Maximum permissible error | Class I | Class II | Class III | Class IIII | 0 ≤ m ≤ 50 000 e | 0 ≤ m ≤ 5 000 e | 0 ≤ m ≤ 500 e | 0 ≤ m ≤ 50 e | ± 0,5 e | 50 000 e < m ≤ 200 000 e | 5 000 e < m ≤ 20 000 e | 500 e < m ≤ 2 000 e | 50 e < m ≤ 200 e | ± 1,0 e | 200 000 e < m | 20 000 e < m ≤ 100 000 e | 2 000 e < m ≤ 10 000 e | 200 e < m ≤ 1 000 e | ± 1,5 e
— eur-lex.europa.eu, retrieved 2026-10-13
Where each value comes from
This source states these in separate places, so each value is shown with the passage it comes from.
Instrument type
1. This Directive shall apply to all non-automatic weighing instruments.
Accuracy class
The source prints this value inside the passage below but does not name it there. The passage shows where it appears; what ties it to this record is the position on the page, not anything the passage says.
Table 3 Maximum permissible errors | Load | Maximum permissible error | Class I
Scope or member state option
The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1.
— all from eur-lex.europa.eu, retrieved 2026-10-13
What oiml.org says
The maximum permissible errors for increasing or decreasing loads are given in Table 6. Table 6 Maximum permissible For loads, m, expressed in verification scale intervals, e errors on initial Class I Class II Class III Class IIII verification ± 0.5 e 0 ≤ m ≤ 50 000 0 ≤ m ≤ 5 000 0 ≤ m ≤ 500 0 ≤ m ≤ 50 ± 1.0 e 50 000 < m ≤ 200 000 5 000 < m ≤ 20 000 500 < m ≤ 2 000 50 < m ≤ 200 ± 1.5 e 200 000 < m 20 000 < m ≤ 100 000 2 000 < m ≤ 10 000 200 < m ≤ 1 000
— oiml.org, retrieved 2026-10-07
Instrument type
This Recommendation specifies the metrological and technical requirements for non-automatic weighing instruments that are subject to official metrological control.
Scope or member state option
The maximum permissible errors in service shall be twice the maximum permissible errors on initial verification (see 8.4.2).
Sources
- eur-lex.europa.euhttps://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32014L0031
- oiml.orghttps://www.oiml.org/en/files/pdf_r/r076-1-e06.pdf