Reference Source

A691 · ½CR, 1CR, 1¼Cr

For A691 · ½CR, 1CR, 1¼Cr, astm specification is A691; class or grade is ½CR, 1CR, 1¼Cr; esab preheat group is C; esab-recommended smaw (stick) filler is AA 8018-CM/7018-B2L; esab-recommended gmaw/gtaw filler is ER80S-B2, recorded from its source on 2026-09-16.

ASTM specification
A691 verified
Class or grade
½CR, 1CR, 1¼Cr verified
ESAB preheat group
C verified
ESAB-recommended SMAW (stick) filler
AA 8018-CM/7018-B2L verified
ESAB-recommended GMAW/GTAW filler
ER80S-B2 verified
ESAB-recommended FCAW (gas-shielded flux-cored) filler
DS 8000-B2/8000-B2L verified
Suggested preheat, low hydrogen (H8 and less), by thickness
T < .75: 200, .75 < T < 1.5: 300, 1.5 < T < 2.5: 300, T > 2.5: 350 our reading
Suggested preheat, hydrogen above H8, by thickness
T < .75: NR, .75 < T < 1.5: NR, 1.5 < T < 2.5: NR, T > 2.5: NR our reading
Sourceassets.esab.com
Verified
Review by
DatasetESAB recommended filler metals and suggested preheat group, by ASTM steel grade

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

What the source says

A691 CM-65, CM-70, CMS-75 B AA 7018-Mo SA 83 CM-75 B AA 8018-NM SA 83 CMSH-70 A AA 7018/7018 Acclaim/8018 Group 1 CMSH-80 A AA 8018/8018-SR SA 75/83 ½CR, 1CR, 1¼Cr C AA 8018-CM/7018-B2L ER80S-B2

assets.esab.com, retrieved 2026-09-16

Where each value comes from

This source states these in separate places, so each value is shown with the passage that states it.

ESAB-recommended FCAW (gas-shielded flux-cored) filler

DS 8000-B2/8000-B2L

Suggested preheat, low hydrogen (H8 and less), by thickness and Suggested preheat, hydrogen above H8, by thickness

Preheat A B C D Low Hydrogen H8 and less T < .75 70 70 200 300 .75 < T < 1.5 70 125 300 400 1.5 < T < 2.5 150 200 300 400 T > 2.5 225 300 350 500 Hydrogen > H8 T < .75 175 175 NR NR .75 < T < 1.5 225 225 NR NR 1.5 < T < 2.5 275 275 NR NR T > 2.5 300 300 NR NR

— all from assets.esab.com, retrieved 2026-09-16

Source