Reference Source

A615 · 60

For A615, class or grade is 60; esab preheat group is A; esab-recommended smaw (stick) filler is AA 9018; esab-recommended gmaw/gtaw filler is SA 83; esab-recommended fcaw (gas-shielded flux-cored) filler is DS II 101H4M/II 101 OS/II 101TC/II 90K2, recorded from its source on 2026-09-16.

ASTM specification
A615 verified
Class or grade
60 verified
ESAB preheat group
A verified
ESAB-recommended SMAW (stick) filler
AA 9018 verified
ESAB-recommended GMAW/GTAW filler
SA 83 verified
ESAB-recommended FCAW (gas-shielded flux-cored) filler
DS II 101H4M/II 101 OS/II 101TC/II 90K2 verified
Suggested preheat by thickness, low hydrogen (H8 and less) — the A-D column for this grade's preheat group
T < .75: 70, .75 < T < 1.5: 70, 1.5 < T < 2.5: 150, T > 2.5: 225 our reading
Suggested preheat by thickness, hydrogen above H8 — the A-D column for this grade's preheat group
T < .75: 175, .75 < T < 1.5: 225, 1.5 < T < 2.5: 275, T > 2.5: 300 our reading
Sourceassets.esab.com
Verified
Review by
DatasetESAB recommended filler metals and suggested preheat group, by ASTM steel grade

Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.

What the source says

A615 40 A AA 7018/7018 Acclaim Group 1 60 A AA 9018 SA 83

— assets.esab.com, retrieved 2026-09-16

Where each value comes from

This source states these in separate places, so each value is shown with the passage it comes from.

ESAB-recommended FCAW (gas-shielded flux-cored) filler

The source prints this value inside the passage below but does not name it there. The passage shows where it appears; what ties it to this record is the position on the page, not anything the passage says.

DS II 101H4M/II 101 OS/II 101TC/II 90K2

Suggested preheat by thickness, low hydrogen (H8 and less) — the A-D column for this grade's preheat group and Suggested preheat by thickness, hydrogen above H8 — the A-D column for this grade's preheat group

Preheat A B C D Low Hydrogen H8 and less T < .75 70 70 200 300 .75 < T < 1.5 70 125 300 400 1.5 < T < 2.5 150 200 300 400 T > 2.5 225 300 350 500 Hydrogen > H8 T < .75 175 175 NR NR .75 < T < 1.5 225 225 NR NR 1.5 < T < 2.5 275 275 NR NR T > 2.5 300 300 NR NR

— all from assets.esab.com, retrieved 2026-09-16

Source

Last verified against source: . Due for re-check by . This page as Markdown · OKF bundle · full dataset as JSON.