Automatic weighing instruments — automatic gravimetric filling instruments
For Automatic weighing instruments, instrument type is Automatic weighing instruments — automatic gravimetric filling instruments; annex is Annex VIII (MI-006); accuracy class is Ref(x); condition is static loads; maximum permissible error is 0,312 of the maximum permissible deviation of each fill from the average, as specified in Table 5, multiplied by the class designation factor (x), recorded from its source on 2026-08-05.
- Instrument type
- Automatic weighing instruments — automatic gravimetric filling instruments
- Annex
- Annex VIII (MI-006)
- Accuracy class
- Ref(x) verified
- Condition
- static loads our reading
- Maximum permissible error
- 0,312 of the maximum permissible deviation of each fill from the average, as specified in Table 5, multiplied by the class designation factor (x) verified
Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.
What the source says
For static loads under rated operating conditions, the MPE for reference accuracy class Ref(x), shall be 0,312 of the maximum permissible deviation of each fill from the average; as specified in Table 5; multiplied by the class designation factor (x).
— eur-lex.europa.eu, retrieved 2026-08-05
Source
- eur-lex.europa.euhttps://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32014L0032