# UF5000 — Solar inverter–battery compatibility For UF5000, inverter brand is Victron; battery brand is Pylontech; nominal voltage is 51.2V; communication interface is CAN-bus; minimum firmware is Venus OS v3.50, recorded from its source on 2026-08-12. - **Inverter brand:** Victron _(verified: appears in the quote below)_ - **Battery brand:** Pylontech _(verified: appears in the quote below)_ - **Battery model:** UF5000 _(verified: appears in the quote below)_ - **Nominal voltage:** 51.2V _(verified: appears in the quote below)_ - **Communication interface:** CAN-bus _(verified: appears in the quote below)_ - **Minimum firmware:** Venus OS v3.50 - **Supported system types:** ESS, Grid Backup, Off-grid - **Module capacity:** Coming soon _(verified: appears in the quote below)_ ## What the source says > CAN-bus Wiring 4. GX Device Settings 5. VEConfigure Settings 6. VE.Direct MPPT Settings 7. Example Wiring Diagram 8. Troubleshooting 9. FAQ and Known Issues The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A. After charging the battery the charge current often changes between 0A and 25A. My system isn't charging at the rated capacity, or my PV is shutting down My system only charges the battery to 52.4V The battery won't charge to 100% 'Internal Error' shown on battery status 'High cell voltage' warning or alarm shown on battery status 10. Further Information DISQUS Victron & Pylontech UP2500, US2000(C/D), US3000, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, Phantom-S, Force-L1 & L2 The combination of Victron products with Pylontech lithium batteries has been tested and certified by the Victron and Pylontech R&D departments. General information about the battery is found in Pylontech's documentation. This manual is intended to be used in conjunction with the product manual supplied by Pylontech. It provides additional and specific information regarding integration with Victron systems. The Pylontech includes a Battery Management System (BMS) with each battery module. This interfaces with the Victron GX device and can support multiple battery modules connected in parallel. 1. Product & system compatibility Battery | UP2500* | US2000 (Plus/C/D) | US3000(C) | UP5000 & US5000(B) | Pelio-L | Force-L1 & L2 | UF5000 | Nominal voltage | 24V | 48V | 48V | 48V | 51.2V | 48V | 51.2V | Module capacity | 2.55 kWh | 2.4 kWh | 3.5 kWh | 4.8 kwh | 5.12kWh | 3.55 kWh | Coming soon | ## Sources disagree More than one authority states this, and they do not state the same thing. Both are reproduced with the source each came from. ### Inverter brand victronenergy.com says inverter brand is **Victron**, as of 2026-08-12. > CAN-bus Wiring 4. GX Device Settings 5. VEConfigure Settings 6. VE.Direct MPPT Settings 7. Example Wiring Diagram 8. Troubleshooting 9. FAQ and Known Issues The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A. After charging the battery the charge current often changes between 0A and 25A. My system isn't charging at the rated capacity, or my PV is shutting down My system only charges the battery to 52.4V The battery won't charge to 100% 'Internal Error' shown on battery status 'High cell voltage' warning or alarm shown on battery status 10. Further Information DISQUS Victron & Pylontech UP2500, US2000(C/D), US3000, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, Phantom-S, Force-L1 & L2 The combination of Victron products with Pylontech lithium batteries has been tested and certified by the Victron and Pylontech R&D departments. General information about the battery is found in Pylontech's documentation. This manual is intended to be used in conjunction with the product manual supplied by Pylontech. It provides additional and specific information regarding integration with Victron systems. The Pylontech includes a Battery Management System (BMS) with each battery module. This interfaces with the Victron GX device and can support multiple battery modules connected in parallel. 1. Product & system compatibility Battery | UP2500* | US2000 (Plus/C/D) | US3000(C) | UP5000 & US5000(B) | Pelio-L | Force-L1 & L2 | UF5000 | Nominal voltage | 24V | 48V | 48V | 48V | 51.2V | 48V | 51.2V | Module capacity | 2.55 kWh | 2.4 kWh | 3.5 kWh | 4.8 kwh | 5.12kWh | 3.55 kWh | Coming soon | Source: https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom pylonwebs3.s3.amazonaws.com says inverter brand is **Voltronic**, as of 2026-08-12. > service@pylontech.com.cn 3/8 Compatibility List of Pylontech ESS and Inverters Ver.2.35.xlsx 48V ESS Last Update: 2025/1/21 Key Features Inverter Activation Inverter Type Battery COMM. Application Force Firmware Ver Brand Charge Multiplus 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid Victron Energy Quattro 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid SI 4.4-M SMA Solar SI 6.0-H d CAN On/off-grid No Yes Technology AG SI 8.0-H SI 6048US Gateway: V1.06 Schneider- Conext XW Pro series CAN On/off-grid Yes Yes XW+ Pro: V1.04(UL) / Electric V1.05 (IEC) GW-BP/SBP CAN On-grid Yes Yes US2000 US2000V2 Goodwe h CAN On-grid Yes Yes GW-ES/ES-C10 US3000 US2000C EM US3000C CAN On-grid Yes Yes IMEON 3.6 US5000 CAN On/off-grid Yes Yes V1.7.6.5 Imeon Energy US5000-B IMEON 9.12 UP5000 CAN On/off-grid Yes Yes V1.7.6.5 UF5000 Xtender 48V serie CAN On/off-grid Yes Yes R652 Phantom-S Studer Innotec VarioString serie Force-L1/L2 CAN On/off-grid Yes Yes R652 Pelio-L VarioTrack 48V serie CAN On/off-grid Yes Yes R652 SPMC 480 CAN On/off-grid No Yes Selectronic SPMC 481 CAN On/off-grid No Yes SPMC 482 CAN On/off-grid No Yes Infinisolar series 48V RS485(9600) On/off-grid Yes Yes V1.00 Voltronic Source: https://pylonwebs3.s3.amazonaws.com/upload_us/2025/02/10/Compatibility%20List%20of%20Pylontech%20ESS%20and%20Inverters%20Ver.2.35_20250210103505A665.pdf ### Nominal voltage victronenergy.com says nominal voltage is **51.2V**, as of 2026-08-12. > CAN-bus Wiring 4. GX Device Settings 5. VEConfigure Settings 6. VE.Direct MPPT Settings 7. Example Wiring Diagram 8. Troubleshooting 9. FAQ and Known Issues The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A. After charging the battery the charge current often changes between 0A and 25A. My system isn't charging at the rated capacity, or my PV is shutting down My system only charges the battery to 52.4V The battery won't charge to 100% 'Internal Error' shown on battery status 'High cell voltage' warning or alarm shown on battery status 10. Further Information DISQUS Victron & Pylontech UP2500, US2000(C/D), US3000, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, Phantom-S, Force-L1 & L2 The combination of Victron products with Pylontech lithium batteries has been tested and certified by the Victron and Pylontech R&D departments. General information about the battery is found in Pylontech's documentation. This manual is intended to be used in conjunction with the product manual supplied by Pylontech. It provides additional and specific information regarding integration with Victron systems. The Pylontech includes a Battery Management System (BMS) with each battery module. This interfaces with the Victron GX device and can support multiple battery modules connected in parallel. 1. Product & system compatibility Battery | UP2500* | US2000 (Plus/C/D) | US3000(C) | UP5000 & US5000(B) | Pelio-L | Force-L1 & L2 | UF5000 | Nominal voltage | 24V | 48V | 48V | 48V | 51.2V | 48V | 51.2V | Module capacity | 2.55 kWh | 2.4 kWh | 3.5 kWh | 4.8 kwh | 5.12kWh | 3.55 kWh | Coming soon | Source: https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom pylonwebs3.s3.amazonaws.com says nominal voltage is **48V**, as of 2026-08-12. > service@pylontech.com.cn 3/8 Compatibility List of Pylontech ESS and Inverters Ver.2.35.xlsx 48V ESS Last Update: 2025/1/21 Key Features Inverter Activation Inverter Type Battery COMM. Application Force Firmware Ver Brand Charge Multiplus 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid Victron Energy Quattro 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid SI 4.4-M SMA Solar SI 6.0-H d CAN On/off-grid No Yes Technology AG SI 8.0-H SI 6048US Gateway: V1.06 Schneider- Conext XW Pro series CAN On/off-grid Yes Yes XW+ Pro: V1.04(UL) / Electric V1.05 (IEC) GW-BP/SBP CAN On-grid Yes Yes US2000 US2000V2 Goodwe h CAN On-grid Yes Yes GW-ES/ES-C10 US3000 US2000C EM US3000C CAN On-grid Yes Yes IMEON 3.6 US5000 CAN On/off-grid Yes Yes V1.7.6.5 Imeon Energy US5000-B IMEON 9.12 UP5000 CAN On/off-grid Yes Yes V1.7.6.5 UF5000 Xtender 48V serie CAN On/off-grid Yes Yes R652 Phantom-S Studer Innotec VarioString serie Force-L1/L2 CAN On/off-grid Yes Yes R652 Pelio-L VarioTrack 48V serie CAN On/off-grid Yes Yes R652 SPMC 480 CAN On/off-grid No Yes Selectronic SPMC 481 CAN On/off-grid No Yes SPMC 482 CAN On/off-grid No Yes Infinisolar series 48V RS485(9600) On/off-grid Yes Yes V1.00 Voltronic Source: https://pylonwebs3.s3.amazonaws.com/upload_us/2025/02/10/Compatibility%20List%20of%20Pylontech%20ESS%20and%20Inverters%20Ver.2.35_20250210103505A665.pdf ### Communication interface victronenergy.com says communication interface is **CAN-bus**, as of 2026-08-12. > CAN-bus Wiring 4. GX Device Settings 5. VEConfigure Settings 6. VE.Direct MPPT Settings 7. Example Wiring Diagram 8. Troubleshooting 9. FAQ and Known Issues The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A. After charging the battery the charge current often changes between 0A and 25A. My system isn't charging at the rated capacity, or my PV is shutting down My system only charges the battery to 52.4V The battery won't charge to 100% 'Internal Error' shown on battery status 'High cell voltage' warning or alarm shown on battery status 10. Further Information DISQUS Victron & Pylontech UP2500, US2000(C/D), US3000, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, Phantom-S, Force-L1 & L2 The combination of Victron products with Pylontech lithium batteries has been tested and certified by the Victron and Pylontech R&D departments. General information about the battery is found in Pylontech's documentation. This manual is intended to be used in conjunction with the product manual supplied by Pylontech. It provides additional and specific information regarding integration with Victron systems. The Pylontech includes a Battery Management System (BMS) with each battery module. This interfaces with the Victron GX device and can support multiple battery modules connected in parallel. 1. Product & system compatibility Battery | UP2500* | US2000 (Plus/C/D) | US3000(C) | UP5000 & US5000(B) | Pelio-L | Force-L1 & L2 | UF5000 | Nominal voltage | 24V | 48V | 48V | 48V | 51.2V | 48V | 51.2V | Module capacity | 2.55 kWh | 2.4 kWh | 3.5 kWh | 4.8 kwh | 5.12kWh | 3.55 kWh | Coming soon | Source: https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom pylonwebs3.s3.amazonaws.com says communication interface is **RS485(9600)**, as of 2026-08-12. > service@pylontech.com.cn 3/8 Compatibility List of Pylontech ESS and Inverters Ver.2.35.xlsx 48V ESS Last Update: 2025/1/21 Key Features Inverter Activation Inverter Type Battery COMM. Application Force Firmware Ver Brand Charge Multiplus 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid Victron Energy Quattro 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid SI 4.4-M SMA Solar SI 6.0-H d CAN On/off-grid No Yes Technology AG SI 8.0-H SI 6048US Gateway: V1.06 Schneider- Conext XW Pro series CAN On/off-grid Yes Yes XW+ Pro: V1.04(UL) / Electric V1.05 (IEC) GW-BP/SBP CAN On-grid Yes Yes US2000 US2000V2 Goodwe h CAN On-grid Yes Yes GW-ES/ES-C10 US3000 US2000C EM US3000C CAN On-grid Yes Yes IMEON 3.6 US5000 CAN On/off-grid Yes Yes V1.7.6.5 Imeon Energy US5000-B IMEON 9.12 UP5000 CAN On/off-grid Yes Yes V1.7.6.5 UF5000 Xtender 48V serie CAN On/off-grid Yes Yes R652 Phantom-S Studer Innotec VarioString serie Force-L1/L2 CAN On/off-grid Yes Yes R652 Pelio-L VarioTrack 48V serie CAN On/off-grid Yes Yes R652 SPMC 480 CAN On/off-grid No Yes Selectronic SPMC 481 CAN On/off-grid No Yes SPMC 482 CAN On/off-grid No Yes Infinisolar series 48V RS485(9600) On/off-grid Yes Yes V1.00 Voltronic Source: https://pylonwebs3.s3.amazonaws.com/upload_us/2025/02/10/Compatibility%20List%20of%20Pylontech%20ESS%20and%20Inverters%20Ver.2.35_20250210103505A665.pdf ### Minimum firmware victronenergy.com says minimum firmware is **Venus OS v3.50**, as of 2026-08-12. > CAN-bus Wiring 4. GX Device Settings 5. VEConfigure Settings 6. VE.Direct MPPT Settings 7. Example Wiring Diagram 8. Troubleshooting 9. FAQ and Known Issues The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A. After charging the battery the charge current often changes between 0A and 25A. My system isn't charging at the rated capacity, or my PV is shutting down My system only charges the battery to 52.4V The battery won't charge to 100% 'Internal Error' shown on battery status 'High cell voltage' warning or alarm shown on battery status 10. Further Information DISQUS Victron & Pylontech UP2500, US2000(C/D), US3000, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, Phantom-S, Force-L1 & L2 The combination of Victron products with Pylontech lithium batteries has been tested and certified by the Victron and Pylontech R&D departments. General information about the battery is found in Pylontech's documentation. This manual is intended to be used in conjunction with the product manual supplied by Pylontech. It provides additional and specific information regarding integration with Victron systems. The Pylontech includes a Battery Management System (BMS) with each battery module. This interfaces with the Victron GX device and can support multiple battery modules connected in parallel. 1. Product & system compatibility Battery | UP2500* | US2000 (Plus/C/D) | US3000(C) | UP5000 & US5000(B) | Pelio-L | Force-L1 & L2 | UF5000 | Nominal voltage | 24V | 48V | 48V | 48V | 51.2V | 48V | 51.2V | Module capacity | 2.55 kWh | 2.4 kWh | 3.5 kWh | 4.8 kwh | 5.12kWh | 3.55 kWh | Coming soon | Source: https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom pylonwebs3.s3.amazonaws.com says minimum firmware is **V1.00**, as of 2026-08-12. > service@pylontech.com.cn 3/8 Compatibility List of Pylontech ESS and Inverters Ver.2.35.xlsx 48V ESS Last Update: 2025/1/21 Key Features Inverter Activation Inverter Type Battery COMM. Application Force Firmware Ver Brand Charge Multiplus 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid Victron Energy Quattro 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid SI 4.4-M SMA Solar SI 6.0-H d CAN On/off-grid No Yes Technology AG SI 8.0-H SI 6048US Gateway: V1.06 Schneider- Conext XW Pro series CAN On/off-grid Yes Yes XW+ Pro: V1.04(UL) / Electric V1.05 (IEC) GW-BP/SBP CAN On-grid Yes Yes US2000 US2000V2 Goodwe h CAN On-grid Yes Yes GW-ES/ES-C10 US3000 US2000C EM US3000C CAN On-grid Yes Yes IMEON 3.6 US5000 CAN On/off-grid Yes Yes V1.7.6.5 Imeon Energy US5000-B IMEON 9.12 UP5000 CAN On/off-grid Yes Yes V1.7.6.5 UF5000 Xtender 48V serie CAN On/off-grid Yes Yes R652 Phantom-S Studer Innotec VarioString serie Force-L1/L2 CAN On/off-grid Yes Yes R652 Pelio-L VarioTrack 48V serie CAN On/off-grid Yes Yes R652 SPMC 480 CAN On/off-grid No Yes Selectronic SPMC 481 CAN On/off-grid No Yes SPMC 482 CAN On/off-grid No Yes Infinisolar series 48V RS485(9600) On/off-grid Yes Yes V1.00 Voltronic Source: https://pylonwebs3.s3.amazonaws.com/upload_us/2025/02/10/Compatibility%20List%20of%20Pylontech%20ESS%20and%20Inverters%20Ver.2.35_20250210103505A665.pdf ### Supported system types victronenergy.com says supported system types is **ESS, Grid Backup, Off-grid**, as of 2026-08-12. > CAN-bus Wiring 4. GX Device Settings 5. VEConfigure Settings 6. VE.Direct MPPT Settings 7. Example Wiring Diagram 8. Troubleshooting 9. FAQ and Known Issues The maximum charge and discharge current is limited to 25A, but the data sheet tells me the maximum is 100A. After charging the battery the charge current often changes between 0A and 25A. My system isn't charging at the rated capacity, or my PV is shutting down My system only charges the battery to 52.4V The battery won't charge to 100% 'Internal Error' shown on battery status 'High cell voltage' warning or alarm shown on battery status 10. Further Information DISQUS Victron & Pylontech UP2500, US2000(C/D), US3000, US3000C, US5000, US5000B, UF5000, Pelio-L, UP5000, Phantom-S, Force-L1 & L2 The combination of Victron products with Pylontech lithium batteries has been tested and certified by the Victron and Pylontech R&D departments. General information about the battery is found in Pylontech's documentation. This manual is intended to be used in conjunction with the product manual supplied by Pylontech. It provides additional and specific information regarding integration with Victron systems. The Pylontech includes a Battery Management System (BMS) with each battery module. This interfaces with the Victron GX device and can support multiple battery modules connected in parallel. 1. Product & system compatibility Battery | UP2500* | US2000 (Plus/C/D) | US3000(C) | UP5000 & US5000(B) | Pelio-L | Force-L1 & L2 | UF5000 | Nominal voltage | 24V | 48V | 48V | 48V | 51.2V | 48V | 51.2V | Module capacity | 2.55 kWh | 2.4 kWh | 3.5 kWh | 4.8 kwh | 5.12kWh | 3.55 kWh | Coming soon | Source: https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom pylonwebs3.s3.amazonaws.com says supported system types is **On/off-grid**, as of 2026-08-12. > service@pylontech.com.cn 3/8 Compatibility List of Pylontech ESS and Inverters Ver.2.35.xlsx 48V ESS Last Update: 2025/1/21 Key Features Inverter Activation Inverter Type Battery COMM. Application Force Firmware Ver Brand Charge Multiplus 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid Victron Energy Quattro 48V (via Venus OS) CAN a Yes Yes 422/V2.15 On/off-grid SI 4.4-M SMA Solar SI 6.0-H d CAN On/off-grid No Yes Technology AG SI 8.0-H SI 6048US Gateway: V1.06 Schneider- Conext XW Pro series CAN On/off-grid Yes Yes XW+ Pro: V1.04(UL) / Electric V1.05 (IEC) GW-BP/SBP CAN On-grid Yes Yes US2000 US2000V2 Goodwe h CAN On-grid Yes Yes GW-ES/ES-C10 US3000 US2000C EM US3000C CAN On-grid Yes Yes IMEON 3.6 US5000 CAN On/off-grid Yes Yes V1.7.6.5 Imeon Energy US5000-B IMEON 9.12 UP5000 CAN On/off-grid Yes Yes V1.7.6.5 UF5000 Xtender 48V serie CAN On/off-grid Yes Yes R652 Phantom-S Studer Innotec VarioString serie Force-L1/L2 CAN On/off-grid Yes Yes R652 Pelio-L VarioTrack 48V serie CAN On/off-grid Yes Yes R652 SPMC 480 CAN On/off-grid No Yes Selectronic SPMC 481 CAN On/off-grid No Yes SPMC 482 CAN On/off-grid No Yes Infinisolar series 48V RS485(9600) On/off-grid Yes Yes V1.00 Voltronic Source: https://pylonwebs3.s3.amazonaws.com/upload_us/2025/02/10/Compatibility%20List%20of%20Pylontech%20ESS%20and%20Inverters%20Ver.2.35_20250210103505A665.pdf ## Source - https://www.victronenergy.com/live/battery_compatibility:pylontech_phantom - https://pylonwebs3.s3.amazonaws.com/upload_us/2025/02/10/Compatibility%20List%20of%20Pylontech%20ESS%20and%20Inverters%20Ver.2.35_20250210103505A665.pdf Last verified: 2026-08-12. Review by: 2027-02-08. Part of [Solar inverter–battery compatibility](https://referencesource.org/solar-inverter-panel-battery-compatibility/).