Supplied-Air Respirator (SAR) or Airline Respirator
For Supplied-Air Respirator (SAR) or Airline Respirator, facepiece is Helmet/hood; operating mode is Continuous flow mode; assigned protection factor is 25/1,000; jurisdiction is 29 CFR 1910.134; conditions is The employer must have evidence provided by the respirator manufacturer that testing of these respirators demonstrates performance at a level of protection of 1,000 or greater to receive an APF of 1,000. This level of performance can best be demonstrated by performing a WPF or SWPF study or equivalent testing. Absent such testing, all other PAPRs and SARs with helmets/hoods are to be treated as loose-fitting facepiece respirators, and receive an APF of 25, recorded from its source on 2026-08-10.
- Respirator type
- Supplied-Air Respirator (SAR) or Airline Respirator verified
- Facepiece
- Helmet/hood our reading
- Operating mode
- Continuous flow mode verified
- Assigned protection factor
- 25/1,000 verified
- Jurisdiction
- 29 CFR 1910.134 our reading
- Conditions
- The employer must have evidence provided by the respirator manufacturer that testing of these respirators demonstrates performance at a level of protection of 1,000 or greater to receive an APF of 1,000. This level of performance can best be demonstrated by performing a WPF or SWPF study or equivalent testing. Absent such testing, all other PAPRs and SARs with helmets/hoods are to be treated as loose-fitting facepiece respirators, and receive an APF of 25. verified
Values marked our reading are our classification of what the source says — the source does not print them in those words. The quote below is the evidence for each one; judge it yourself.
What the source says
Type of respirator 1 2 | Quarter mask | Half mask | Full facepiece | Helmet/hood | Loose-fitting facepiece | 1. Air-Purifying Respirator | 5 | 3 10 | 50 | | | 2. Powered Air-Purifying Respirator (PAPR) | | 50 | 1,000 | 4 25/1,000 | 25 | 3. Supplied-Air Respirator (SAR) or Airline Respirator | | | | | | • Demand mode | | 10 | 50 | | | • Continuous flow mode | | 50 | 1,000 | 4 25/1,000 | 25 | • Pressure-demand or other positive-pressure mode | | 50 | 1,000 | | | 4. Self-Contained Breathing Apparatus (SCBA) | | | | | | • Demand mode | | 10 | 50 | 50 | | • Pressure-demand or other positive-pressure mode (e.g., open/closed circuit) | | | 10,000 | 10,000 | | Notes: | 1 Employers may select respirators assigned for use in higher workplace concentrations of a hazardous substance for use at lower concentrations of that substance, or when required respirator use is independent of concentration. | 2 The assigned protection factors in Table 1 are only effective when the employer implements a continuing, effective respirator program as required by this section ( <https://www.ecfr.gov/current/title-29/section-1910.134> 29 CFR 1910.134 ), including training, fit testing, maintenance, and use requirements. | 3 This APF category includes filtering facepieces, and half masks with elastomeric facepieces. | 4 The employer must have evidence provided by the respirator manufacturer that testing of these respirators demonstrates performance at a level of protection of 1,000 or greater to receive an APF of 1,000. This level of performance can best be demonstrated by performing a WPF or SWPF study or equivalent testing. Absent such testing, all other PAPRs and SARs with helmets/hoods are to be treated as loose-fitting facepiece respirators, and receive an APF of 25. |
— ecfr.gov, retrieved 2026-08-10
Source
- ecfr.govhttps://www.ecfr.gov/current/title-29/subtitle-B/chapter-XVII/part-1910/subpart-I/section-1910.134