# Water meters · Annex III · durability test, error of indication, Q2 to Q4, water 30 °C to 90 °C — Accuracy classes and maximum permissible errors for trade measuring instruments For Water meters, annex is Annex III; condition is durability test, error of indication, Q2 to Q4, water 30 °C to 90 °C; maximum permissible error is ± 3,5 %, recorded from its source on 2026-09-01. - **Instrument type:** Water meters _(verified: appears in its own passage below)_ - **Annex:** Annex III _(verified: appears in its own passage below)_ - **Condition:** durability test, error of indication, Q2 to Q4, water 30 °C to 90 °C _(our reading, not quoted from the source)_ - **Maximum permissible error:** ± 3,5 % _(verified: appears in its own passage below)_ ## What the source says > The error of indication for the volume metered after the durability test shall not exceed: — | ± 6 % of the metered volume between Q1 included and Q2 excluded; | — | ± 2,5 % of the metered volume between Q2 included and Q4 included for water meters intended to meter water with a temperature between 0,1 °C and 30 °C, | — | ± 3,5 % of the metered volume between Q2 included and Q4 included for water meters intended to meter water with a temperature between 30 °C and 90 °C. ## Where each value comes from This source states these in separate places, so each value is shown with the passage that states it. ### Instrument type > ANNEX III WATER METERS (MI-001) The relevant requirements of Annex I, the specific requirements of this Annex and the conformity assessment procedures listed in this Annex, apply to water meters intended for the measurement of volumes of clean, cold or heated water in residential, commercial and light industrial use. ### Annex > ANNEX III WATER METERS (MI-001) ### Maximum permissible error > ± 3,5 % of the metered volume between Q2 included and Q4 included for water meters intended to meter water with a temperature between 30 °C and 90 °C. ## Source - https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32014L0032 Last verified: 2026-09-01. Review by: 2027-09-01. Part of [Accuracy classes and maximum permissible errors for trade measuring instruments](https://referencesource.org/legal-metrology-accuracy-classes/).