# Scales ยท class II, test load 20 001 + e, maintenance tolerance โ€” Accuracy classes and maximum permissible errors for trade measuring instruments For Scales, condition is class II, test load 20 001 + e, maintenance tolerance; accuracy class is II; maximum permissible error is 3; scope or member state option is The acceptance tolerance values shall be one-half the maintenance tolerance values, recorded from its source on 2026-10-13. - **Instrument type:** Scales _(verified: appears in its own passage below)_ - **Accuracy class:** II _(verified: appears in the quote below)_ - **Condition:** class II, test load 20 001 + e, maintenance tolerance _(our reading, not quoted from the source)_ - **Maximum permissible error:** 3 _(verified: appears in its own passage below)_ - **Scope or member state option:** The acceptance tolerance values shall be one-half the maintenance tolerance values. _(verified: appears in its own passage below)_ ## What the source says **Accuracy class:** The source prints this value inside the passage below but does not name it there. The passage shows where it appears; what ties it to this record is the position on the page, not anything the passage says. > Table 6. Maintenance Tolerances (All values in this table are in verification scale intervals (e)) Tolerance 1 2 3 5 Class Test Load Applied I 0 to 50 000 50 001 to 200 000 200 001 + II 0 to 5 000 5 001 to 20 000 20 001 + ## Where each value comes from This source states these in separate places, so each value is shown with the passage that states it. ### Instrument type > Section 2.20. Scales A. Application A.1. General. โ€“ This code applies to all types of weighing devices other than automatic bulk-weighing systems, belt-conveyor scales, and automatic weighing systems. ### Maximum permissible error > Table 6. Maintenance Tolerances (All values in this table are in verification scale intervals (e)) Tolerance 1 2 3 5 Class Test Load Applied I 0 to 50 000 50 001 to 200 000 200 001 + II 0 to 5 000 5 001 to 20 000 20 001 + ### Scope or member state option > T.N.3.2. Acceptance Tolerance Values. โ€“ The acceptance tolerance values shall be one-half the maintenance tolerance values. ## Source - https://www.nist.gov/document/2026-nist-handbook-44-section-220 Last verified: 2026-10-13. Review by: 2027-10-13. Part of [Accuracy classes and maximum permissible errors for trade measuring instruments](https://referencesource.org/legal-metrology-accuracy-classes/).