# Non-automatic weighing instruments · class I, load 50 000 e < m ≤ 200 000 e, on initial verification — Accuracy classes and maximum permissible errors for trade measuring instruments For Non-automatic weighing instruments, condition is class I, load 50 000 e < m ≤ 200 000 e, on initial verification; accuracy class is I; maximum permissible error is ± 1,0 e; scope or member state option is The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1, recorded from its source on 2026-10-13. - **Instrument type:** Non-automatic weighing instruments _(verified: appears in its own passage below)_ - **Accuracy class:** I _(verified: appears in its own passage below)_ - **Condition:** class I, load 50 000 e < m ≤ 200 000 e, on initial verification _(our reading, not quoted from the source)_ - **Maximum permissible error:** ± 1,0 e _(verified: appears in the quote below)_ - **Scope or member state option:** The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1. _(verified: appears in its own passage below)_ ## What the source says > Table 3 Maximum permissible errors | Load | Maximum permissible error | Class I | Class II | Class III | Class IIII | 0 ≤ m ≤ 50 000 e | 0 ≤ m ≤ 5 000 e | 0 ≤ m ≤ 500 e | 0 ≤ m ≤ 50 e | ± 0,5 e | 50 000 e < m ≤ 200 000 e | 5 000 e < m ≤ 20 000 e | 500 e < m ≤ 2 000 e | 50 e < m ≤ 200 e | ± 1,0 e ## Where each value comes from This source states these in separate places, so each value is shown with the passage it comes from. ### Instrument type > 1. This Directive shall apply to all non-automatic weighing instruments. ### Accuracy class The source prints this value inside the passage below but does not name it there. The passage shows where it appears; what ties it to this record is the position on the page, not anything the passage says. > Table 3 Maximum permissible errors | Load | Maximum permissible error | Class I ### Scope or member state option > The maximum permissible errors in service are twice the maximum permissible errors fixed in Section 4.1. ## What oiml.org says > The maximum permissible errors for increasing or decreasing loads are given in Table 6. Table 6 Maximum permissible For loads, m, expressed in verification scale intervals, e errors on initial Class I Class II Class III Class IIII verification ± 0.5 e 0 ≤ m ≤ 50 000 0 ≤ m ≤ 5 000 0 ≤ m ≤ 500 0 ≤ m ≤ 50 ± 1.0 e 50 000 < m ≤ 200 000 5 000 < m ≤ 20 000 500 < m ≤ 2 000 50 < m ≤ 200 **Instrument type:** > This Recommendation specifies the metrological and technical requirements for non-automatic weighing instruments that are subject to official metrological control. **Scope or member state option:** > The maximum permissible errors in service shall be twice the maximum permissible errors on initial verification (see 8.4.2). Source: https://www.oiml.org/en/files/pdf_r/r076-1-e06.pdf ## Source - https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32014L0031 - https://www.oiml.org/en/files/pdf_r/r076-1-e06.pdf Last verified: 2026-10-13. Review by: 2027-10-13. Part of [Accuracy classes and maximum permissible errors for trade measuring instruments](https://referencesource.org/legal-metrology-accuracy-classes/).