  "name": "EPCRA Tier II hazardous chemical inventory reporting thresholds by state",
  "description": "The quantity threshold at which a facility must file an annual Tier II hazardous chemical inventory report in each US state, compared to the federal EPCRA Section 312 baseline. Federal thresholds: \u226510,000 lbs for hazardous chemicals, \u2265500 lbs or the threshold planning quantity (whichever is lower) for extremely hazardous substances (40 CFR Part 370). EPA authorizes states to set lower thresholds and add chemicals, and at least 9 states have done so: California (55 gal/500 lbs), Louisiana (500 lbs), Vermont (100 lbs \u2014 among the strictest), Delaware (55 gal/500 lbs), Oregon (dual-level system), Nevada (IFC-based, some categories at 0 lbs), Alaska (any quantity for certain hazard classes), New Jersey (own EHS list), and New York City (own EHS list with very low thresholds). Answers 'does my California facility need to file Tier II for 600 pounds of a hazardous chemical' (yes \u2014 California threshold is 500 lbs, below the federal 10,000), 'what is Nevada's reporting threshold for flammable materials', and 'which states have lower Tier II thresholds than federal'.",
  "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/",
  "licence": "Federal regulations are US Government works, not copyrightable. State regulations are state government works. Facts are not copyrightable (Feist, 1991); each record quotes a short attributed span and links back.",
  "last_verified": "2026-08-15",
  "stale_after": "2027-08-15",
  "sources": [
    "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
    "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
    "https://www.epa.gov/epcra/tier-ii-forms-and-instructions",
    "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-J/part-370"
  ],
  "records": [
    {
      "jurisdiction": "Alaska",
      "general_threshold": "10,000 pounds (federal threshold for non-placarded chemicals)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "Poison Gas Hazard Division 2.3 and Poisons 6.1: any quantity; Explosives 1.1, 1.2 and 1.3 (excluding smokeless gunpowder, black powder, and ammunition): any quantity; Flammable Solid Divisions 4.1, 4.2 and 4.3: any quantity; Radioactive Hazard Class 7: any quantity; Compressed gas: \u22651,000 cubic feet",
      "filing_deadline": "March 1",
      "id": "alaska",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/alaska/",
      "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
      "source_quote": "Alaska, the lower thresholds apply to any quantity of a hazardous material identified in federal placarding regulations: Poison Gas Hazard Division 2.3 and Poisons 6.1, Explosives 1.1, 1.2 and 1.3 (excluding smokeless gunpowder, black powder, and ammunition), Flammable Solid Divisions 4.1, 4.2 and 4.3, and Radioactive Hazard Class 7. Additionally, any compressed gas must be reported at \u22651,000 cubic feet.",
      "verified_fields": [
        "jurisdiction",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "California",
      "general_threshold": "55 gallons (liquids), 500 pounds (solids), 200 cubic feet (compressed gasses)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "Any quantity of hazardous waste",
      "report_name": "Hazardous Materials Business Plan",
      "filing_deadline": "March 1",
      "id": "california",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/california/",
      "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
      "source_quote": "California, the hazardous materials report is called a Hazardous Materials Business Plan and is significantly more in-depth than a standard Tier II report. The reporting thresholds for California are: 55 gallons (liquids) 500 pounds (solids) 200 cubic feet (compressed gasses) Any quantity of hazardous waste",
      "verified_fields": [
        "general_threshold",
        "jurisdiction",
        "report_name",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ],
      "disagreements": [
        {
          "field": "general_threshold",
          "versions": [
            {
              "value": "55 gallons (liquids), 500 pounds (solids), 200 cubic feet (compressed gasses)",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "California, the hazardous materials report is called a Hazardous Materials Business Plan and is significantly more in-depth than a standard Tier II report. The reporting thresholds for California are: 55 gallons (liquids) 500 pounds (solids) 200 cubic feet (compressed gasses) Any quantity of hazardous waste",
              "as_of": "2026-08-15"
            },
            {
              "value": "500 pounds for solids, 55 gallons for liquids, 200 cubic feet for compressed gases",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "California: 500 pounds for solids 55 gallons for liquids 200 cubic feet for compressed gases Report deadlines can vary depending on the local CUPA. Submissions are part of the broader Hazardous Materials Business Plan (HMBP) under CERS.",
              "as_of": "2026-08-15"
            }
          ]
        },
        {
          "field": "special_categories",
          "versions": [
            {
              "value": "Any quantity of hazardous waste",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "California, the hazardous materials report is called a Hazardous Materials Business Plan and is significantly more in-depth than a standard Tier II report. The reporting thresholds for California are: 55 gallons (liquids) 500 pounds (solids) 200 cubic feet (compressed gasses) Any quantity of hazardous waste",
              "as_of": "2026-08-15"
            },
            {
              "value": "Report deadlines can vary depending on the local CUPA",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "California: 500 pounds for solids 55 gallons for liquids 200 cubic feet for compressed gases Report deadlines can vary depending on the local CUPA. Submissions are part of the broader Hazardous Materials Business Plan (HMBP) under CERS.",
              "as_of": "2026-08-15"
            }
          ]
        },
        {
          "field": "report_name",
          "versions": [
            {
              "value": "Hazardous Materials Business Plan",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "California, the hazardous materials report is called a Hazardous Materials Business Plan and is significantly more in-depth than a standard Tier II report. The reporting thresholds for California are: 55 gallons (liquids) 500 pounds (solids) 200 cubic feet (compressed gasses) Any quantity of hazardous waste",
              "as_of": "2026-08-15"
            },
            {
              "value": "Hazardous Materials Business Plan (HMBP)",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "California: 500 pounds for solids 55 gallons for liquids 200 cubic feet for compressed gases Report deadlines can vary depending on the local CUPA. Submissions are part of the broader Hazardous Materials Business Plan (HMBP) under CERS.",
              "as_of": "2026-08-15"
            }
          ]
        },
        {
          "field": "filing_deadline",
          "versions": [
            {
              "value": "March 1",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "California, the hazardous materials report is called a Hazardous Materials Business Plan and is significantly more in-depth than a standard Tier II report. The reporting thresholds for California are: 55 gallons (liquids) 500 pounds (solids) 200 cubic feet (compressed gasses) Any quantity of hazardous waste",
              "as_of": "2026-08-15"
            },
            {
              "value": "Varies by local CUPA",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "California: 500 pounds for solids 55 gallons for liquids 200 cubic feet for compressed gases Report deadlines can vary depending on the local CUPA. Submissions are part of the broader Hazardous Materials Business Plan (HMBP) under CERS.",
              "as_of": "2026-08-15"
            }
          ]
        }
      ]
    },
    {
      "jurisdiction": "Colorado",
      "general_threshold": "10,000 pounds (federal)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "Requires use of Tier2 Submit; some LEPCs and fire departments may require additional reporting elements",
      "report_name": "Tier II",
      "filing_deadline": "March 1",
      "id": "colorado",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/colorado/",
      "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
      "source_quote": "Colorado: Requires use of Tier2 Submit. The state distributes reports to LEPCs and fire departments that maintain the same reporting requirements. Some LEPCs and fire departments may require additional reporting elements.",
      "verified_fields": [
        "jurisdiction",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "Connecticut",
      "general_threshold": "10,000 pounds (federal)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "Requires Tier II reports to be submitted directly to local fire departments, often with unique local formatting and mapping requirements",
      "report_name": "Tier II",
      "filing_deadline": "March 1",
      "id": "connecticut",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/connecticut/",
      "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
      "source_quote": "Connecticut: Requires Tier II reports to be submitted directly to local fire departments, often with unique local formatting and mapping requirements.",
      "verified_fields": [
        "jurisdiction",
        "report_name",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "Delaware",
      "general_threshold": "55 gallons or 500 pounds, whichever is lower",
      "ehs_threshold": "Threshold Planning Quantity (TPQ) if lower than 55 gallons or 500 pounds",
      "special_categories": "Chemicals used exclusively for heating the facility: 10,000-pound threshold",
      "filing_deadline": "March 1",
      "id": "delaware",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/delaware/",
      "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
      "source_quote": "Delaware, the reporting threshold is 55 gallons or 500 pounds for hazardous materials, whichever is lower, unless the Threshold Planning Quantity (TPQ) is lowest, in which case it must be used. The only chemicals with a 10,000-pound threshold are those which are used exclusively for heating the facility.",
      "verified_fields": [
        "ehs_threshold",
        "jurisdiction",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "Federal (baseline)",
      "general_threshold": "10,000 pounds",
      "ehs_threshold": "500 pounds or the Threshold Planning Quantity (TPQ), whichever is lower",
      "special_categories": "Gasoline at retail gas station: 75,000 gallons (all grades combined, tank(s) entirely underground in UST compliance); Diesel fuel at retail gas station: 100,000 gallons (all grades combined, tank(s) entirely underground in UST compliance)",
      "report_name": "Tier II",
      "filing_deadline": "March 1",
      "regulatory_citation": "40 CFR Part 370",
      "id": "federal-baseline",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/federal-baseline/",
      "source": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-J/part-370",
      "source_quote": "the threshold level is 10,000 pounds (or 4,540 kg).",
      "verified_fields": [
        "general_threshold"
      ],
      "derived_fields": [
        "filing_deadline",
        "regulatory_citation"
      ],
      "disagreements": [
        {
          "field": "regulatory_citation",
          "versions": [
            {
              "value": "40 CFR Part 370",
              "source": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-J/part-370",
              "source_quote": "the threshold level is 10,000 pounds (or 4,540 kg).",
              "as_of": "2026-08-15"
            },
            {
              "value": "42 U.S.C. 11022, EPCRA Section 312",
              "source": "https://www.epa.gov/epcra/tier-ii-forms-and-instructions",
              "source_quote": "requires the owner or operator of facilities subject to Section 311 of EPCRA",
              "as_of": "2026-08-15"
            }
          ]
        }
      ]
    },
    {
      "jurisdiction": "Florida",
      "general_threshold": "10,000 pounds (federal)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "Accepts Tier II reports through E-Plan; imposes additional requirements related to facility emergency contacts and notifications",
      "report_name": "Tier II",
      "filing_deadline": "March 1",
      "id": "florida",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/florida/",
      "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
      "source_quote": "Florida: Accepts Tier II reports through E-Plan and imposes additional requirements related to facility emergency contacts and notifications.",
      "verified_fields": [
        "jurisdiction",
        "report_name",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "Illinois",
      "general_threshold": "10,000 pounds (federal)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "Uses the state-managed SERC portal with specific formatting expectations for site maps",
      "report_name": "Tier II",
      "filing_deadline": "March 1",
      "id": "illinois",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/illinois/",
      "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
      "source_quote": "Illinois: Uses the state-managed SERC portal with specific formatting expectations for site maps.",
      "verified_fields": [
        "jurisdiction",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "Louisiana",
      "general_threshold": "500 pounds",
      "ehs_threshold": "Threshold Planning Quantity (TPQ) if lower than 500 pounds",
      "special_categories": "Used oil must also be reported",
      "filing_deadline": "March 1",
      "id": "louisiana",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/louisiana/",
      "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
      "source_quote": "Louisiana, the reporting threshold is 500 pounds for any hazardous materials unless the Threshold Planning Quantity (TPQ) is lower, in which case it must be used. In addition to the lower threshold, used oil must also be reported.",
      "verified_fields": [
        "ehs_threshold",
        "general_threshold",
        "jurisdiction",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ],
      "disagreements": [
        {
          "field": "general_threshold",
          "versions": [
            {
              "value": "500 pounds",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "Louisiana, the reporting threshold is 500 pounds for any hazardous materials unless the Threshold Planning Quantity (TPQ) is lower, in which case it must be used. In addition to the lower threshold, used oil must also be reported.",
              "as_of": "2026-08-15"
            },
            {
              "value": "500 pounds for any hazardous material unless the TPQ is lower",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "Louisiana: 500 pounds for any hazardous material unless the TPQ is lower. Requires attention to both state and parish-level expectations.",
              "as_of": "2026-08-15"
            }
          ]
        }
      ]
    },
    {
      "jurisdiction": "Nevada",
      "general_threshold": "Determined using the International Fire Code List (IFC); thresholds range from 0 to 500 lbs depending on material type",
      "ehs_threshold": "Federal thresholds apply for chemicals not in IFC categories",
      "special_categories": "Flammable materials to water-reactive materials have IFC-specific thresholds; no exemptions can be applied to IFC-category materials; if a chemical does not apply to an IFC category, federal Tier II thresholds and federal exemptions apply",
      "report_name": "Community Right-to-Know Act",
      "filing_deadline": "March 1",
      "id": "nevada",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/nevada/",
      "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
      "source_quote": "Nevada, the hazardous material storage report is called the Community Right-to-Know Act. The reporting thresholds in Nevada are determined using the International Fire Code List (IFC). The different material types range from flammable materials to water-reactive materials and have thresholds ranging from 0 to 500 lbs.",
      "verified_fields": [
        "general_threshold",
        "jurisdiction",
        "report_name"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "Nevada (Clark County)",
      "general_threshold": "International Fire Code (IFC) thresholds, often triggering reporting at much lower quantities than the federal 10,000-pound standard",
      "special_categories": "Submission functions as both an EPCRA report and a State Fire Marshal operating permit; dual reporting period; additional recordkeeping requirements and local hazardous materials fees",
      "filing_deadline": "March 1",
      "id": "nevada-clark-county",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/nevada-clark-county/",
      "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
      "source_quote": "Nevada (Clark County): Tier II reporting differs from most states because it relies on International Fire Code (IFC) thresholds rather than the federal 10,000-pound standard, often triggering reporting at much lower quantities for common chemicals.",
      "verified_fields": [
        "general_threshold",
        "jurisdiction"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "New Jersey",
      "general_threshold": "State-specific EHS list determines chemical-specific reporting threshold",
      "ehs_threshold": "New Jersey has its own EHS list with chemical-specific thresholds",
      "special_categories": "State EHS list is substantially larger than the federal list and includes solids deemed \"unusually hazardous substances\"; NAICS Code assessment required \u2014 facilities without a covered NAICS Code are exempt from reporting",
      "report_name": "Community Right to Know Program",
      "filing_deadline": "March 1",
      "id": "new-jersey",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/new-jersey/",
      "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
      "source_quote": "New Jersey \u2013 The hazardous material storage report for New Jersey is referred to as the Community Right to Know Program.",
      "verified_fields": [
        "jurisdiction",
        "report_name"
      ],
      "derived_fields": [
        "filing_deadline"
      ],
      "disagreements": [
        {
          "field": "general_threshold",
          "versions": [
            {
              "value": "State-specific EHS list determines chemical-specific reporting threshold",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "New Jersey \u2013 The hazardous material storage report for New Jersey is referred to as the Community Right to Know Program.",
              "as_of": "2026-08-15"
            },
            {
              "value": "500 pounds if RQ is not listed; 10,000 pounds if chemical is not listed",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "New Jersey: Facilities are subject to the New Jersey Environmental Hazardous Substance (EHS) list. This list contains thresholds that are lower than federal thresholds. 500 pounds if RQ is not listed 10,000 pounds if chemical is not listed.",
              "as_of": "2026-08-15"
            }
          ]
        },
        {
          "field": "ehs_threshold",
          "versions": [
            {
              "value": "New Jersey has its own EHS list with chemical-specific thresholds",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "New Jersey \u2013 The hazardous material storage report for New Jersey is referred to as the Community Right to Know Program.",
              "as_of": "2026-08-15"
            },
            {
              "value": "New Jersey Environmental Hazardous Substance (EHS) list determines thresholds",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "New Jersey: Facilities are subject to the New Jersey Environmental Hazardous Substance (EHS) list. This list contains thresholds that are lower than federal thresholds. 500 pounds if RQ is not listed 10,000 pounds if chemical is not listed.",
              "as_of": "2026-08-15"
            }
          ]
        },
        {
          "field": "special_categories",
          "versions": [
            {
              "value": "State EHS list is substantially larger than the federal list and includes solids deemed \"unusually hazardous substances\"; NAICS Code assessment required \u2014 facilities without a covered NAICS Code are exempt from reporting",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "New Jersey \u2013 The hazardous material storage report for New Jersey is referred to as the Community Right to Know Program.",
              "as_of": "2026-08-15"
            },
            {
              "value": "Facilities are subject to the New Jersey Environmental Hazardous Substance (EHS) list with thresholds lower than federal",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "New Jersey: Facilities are subject to the New Jersey Environmental Hazardous Substance (EHS) list. This list contains thresholds that are lower than federal thresholds. 500 pounds if RQ is not listed 10,000 pounds if chemical is not listed.",
              "as_of": "2026-08-15"
            }
          ]
        }
      ]
    },
    {
      "jurisdiction": "New York",
      "general_threshold": "10,000 pounds (federal)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "State agencies accept Tier II reports via E-Plan",
      "report_name": "Tier II",
      "filing_deadline": "March 1",
      "id": "new-york",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/new-york/",
      "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
      "source_quote": "New York: State agencies accept Tier II reports via E-Plan.",
      "verified_fields": [
        "jurisdiction",
        "report_name",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "New York City",
      "general_threshold": "Federal thresholds apply if CAS number is not on the NYC EHS list",
      "ehs_threshold": "NYC has its own EHS list with very low reporting thresholds",
      "special_categories": "For any pure substance, if the CAS number is on the NYC EHS list and is stored over the threshold, it must be reported",
      "report_name": "Community Right-to-Know Program",
      "filing_deadline": "March 1",
      "id": "new-york-city",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/new-york-city/",
      "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
      "source_quote": "New York City is also referred to as the Community Right-to-Know Program and must be completed in addition to the New York state report. New York City has its own EHS list with very low reporting thresholds. For any pure substance, if the CAS number is on the NYC EHS list and is stored over the threshold, it must be reported. However, if not on the list, federal thresholds apply.",
      "verified_fields": [
        "ehs_threshold",
        "general_threshold",
        "jurisdiction",
        "report_name",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ],
      "disagreements": [
        {
          "field": "general_threshold",
          "versions": [
            {
              "value": "Federal thresholds apply if CAS number is not on the NYC EHS list",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "New York City is also referred to as the Community Right-to-Know Program and must be completed in addition to the New York state report. New York City has its own EHS list with very low reporting thresholds. For any pure substance, if the CAS number is on the NYC EHS list and is stored over the threshold, it must be reported. However, if not on the list, federal thresholds apply.",
              "as_of": "2026-08-15"
            },
            {
              "value": "Lower thresholds; separate Facility Inventory Form (FIF) required",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "New York City, however, administers its own program with lower thresholds and requires a separate Facility Inventory Form (FIF).",
              "as_of": "2026-08-15"
            }
          ]
        },
        {
          "field": "ehs_threshold",
          "versions": [
            {
              "value": "NYC has its own EHS list with very low reporting thresholds",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "New York City is also referred to as the Community Right-to-Know Program and must be completed in addition to the New York state report. New York City has its own EHS list with very low reporting thresholds. For any pure substance, if the CAS number is on the NYC EHS list and is stored over the threshold, it must be reported. However, if not on the list, federal thresholds apply.",
              "as_of": "2026-08-15"
            },
            {
              "value": "NYC-specific lower thresholds",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "New York City, however, administers its own program with lower thresholds and requires a separate Facility Inventory Form (FIF).",
              "as_of": "2026-08-15"
            }
          ]
        },
        {
          "field": "special_categories",
          "versions": [
            {
              "value": "For any pure substance, if the CAS number is on the NYC EHS list and is stored over the threshold, it must be reported",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "New York City is also referred to as the Community Right-to-Know Program and must be completed in addition to the New York state report. New York City has its own EHS list with very low reporting thresholds. For any pure substance, if the CAS number is on the NYC EHS list and is stored over the threshold, it must be reported. However, if not on the list, federal thresholds apply.",
              "as_of": "2026-08-15"
            },
            {
              "value": "Administers its own program separate from New York State; requires a separate Facility Inventory Form (FIF)",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "New York City, however, administers its own program with lower thresholds and requires a separate Facility Inventory Form (FIF).",
              "as_of": "2026-08-15"
            }
          ]
        },
        {
          "field": "report_name",
          "versions": [
            {
              "value": "Community Right-to-Know Program",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "New York City is also referred to as the Community Right-to-Know Program and must be completed in addition to the New York state report. New York City has its own EHS list with very low reporting thresholds. For any pure substance, if the CAS number is on the NYC EHS list and is stored over the threshold, it must be reported. However, if not on the list, federal thresholds apply.",
              "as_of": "2026-08-15"
            },
            {
              "value": "Facility Inventory Form (FIF)",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "New York City, however, administers its own program with lower thresholds and requires a separate Facility Inventory Form (FIF).",
              "as_of": "2026-08-15"
            }
          ]
        }
      ]
    },
    {
      "jurisdiction": "Oregon",
      "general_threshold": "Dual-level reporting system; Upper Reporting Levels (URL): 500 gallons (liquids), 500 pounds (solids), 500 cubic feet (non-liquefied gases), 500 gallons (liquefied gases)",
      "ehs_threshold": "Lower Reporting Levels (LRL) for highly toxic or explosive substances: 5 gallons (liquids), 10 pounds (solids), 20 cubic feet (compressed gasses)",
      "special_categories": "Non-sealed radioactive: reportable at any amount",
      "filing_deadline": "March 1",
      "id": "oregon",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/oregon/",
      "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
      "source_quote": "Oregon are determined using a dual-level reporting system. Substances that are highly toxic or explosive apply to the Lower Reporting Levels (LRL). 5 gallons (liquids) 10 pounds (solids) 20 cubic feet (compressed gasses) Non-sealed radioactive: reportable at any amount All other substances must adhere to the Upper Reporting Levels (URL): 500 gallons (liquids) 500 pounds (solids) 500 cubic feet (non-liquefied gases) 500 gallons (liquefied gases)",
      "verified_fields": [
        "ehs_threshold",
        "general_threshold",
        "jurisdiction",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ],
      "disagreements": [
        {
          "field": "general_threshold",
          "versions": [
            {
              "value": "Dual-level reporting system; Upper Reporting Levels (URL): 500 gallons (liquids), 500 pounds (solids), 500 cubic feet (non-liquefied gases), 500 gallons (liquefied gases)",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "Oregon are determined using a dual-level reporting system. Substances that are highly toxic or explosive apply to the Lower Reporting Levels (LRL). 5 gallons (liquids) 10 pounds (solids) 20 cubic feet (compressed gasses) Non-sealed radioactive: reportable at any amount All other substances must adhere to the Upper Reporting Levels (URL): 500 gallons (liquids) 500 pounds (solids) 500 cubic feet (non-liquefied gases) 500 gallons (liquefied gases)",
              "as_of": "2026-08-15"
            },
            {
              "value": "Dual-level system",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "Oregon: Requires a detailed site diagram.",
              "as_of": "2026-08-15"
            }
          ]
        },
        {
          "field": "special_categories",
          "versions": [
            {
              "value": "Non-sealed radioactive: reportable at any amount",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "Oregon are determined using a dual-level reporting system. Substances that are highly toxic or explosive apply to the Lower Reporting Levels (LRL). 5 gallons (liquids) 10 pounds (solids) 20 cubic feet (compressed gasses) Non-sealed radioactive: reportable at any amount All other substances must adhere to the Upper Reporting Levels (URL): 500 gallons (liquids) 500 pounds (solids) 500 cubic feet (non-liquefied gases) 500 gallons (liquefied gases)",
              "as_of": "2026-08-15"
            },
            {
              "value": "Requires a detailed site diagram",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "Oregon: Requires a detailed site diagram.",
              "as_of": "2026-08-15"
            }
          ]
        }
      ]
    },
    {
      "jurisdiction": "South Carolina",
      "general_threshold": "10,000 pounds (federal)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "Requires exclusive use of E-Plan for state submissions",
      "report_name": "Tier II",
      "filing_deadline": "March 1",
      "id": "south-carolina",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/south-carolina/",
      "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
      "source_quote": "South Carolina: Requires exclusive use of E-Plan for state submissions.",
      "verified_fields": [
        "jurisdiction",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "Texas",
      "general_threshold": "10,000 pounds (federal)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "All facilities must submit using the STEERS Tier II Reporting system",
      "report_name": "Tier II",
      "filing_deadline": "March 1",
      "id": "texas",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/texas/",
      "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
      "source_quote": "Texas: All facilities must submit using the STEERS Tier II Reporting system.",
      "verified_fields": [
        "jurisdiction",
        "report_name",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    },
    {
      "jurisdiction": "Vermont",
      "general_threshold": "100 pounds or the TPQ, whichever is lower",
      "ehs_threshold": "100 pounds or the TPQ, whichever is lower",
      "special_categories": "Petroleum products and fuels: \u226510,000 lbs; Carcinogens: any amount; Explosives: any amount",
      "filing_deadline": "March 1",
      "id": "vermont",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/vermont/",
      "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
      "source_quote": "Vermont, the state-specific reporting thresholds are as follows: For all EHSs, as well as all other hazardous chemicals or substances and pesticides for which an SDS is required, the threshold is 100 pounds or the TPQ, whichever is lower. For all petroleum products and fuels, the threshold is \u226510,000 lbs Carcinogens must be reported at any amount Explosives must be reported at any amount",
      "verified_fields": [
        "ehs_threshold",
        "general_threshold",
        "jurisdiction",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ],
      "disagreements": [
        {
          "field": "special_categories",
          "versions": [
            {
              "value": "Petroleum products and fuels: \u226510,000 lbs; Carcinogens: any amount; Explosives: any amount",
              "source": "https://www.uscompliance.com/blog/hazardous-material-storage-reports-with-non-federal-thresholds/",
              "source_quote": "Vermont, the state-specific reporting thresholds are as follows: For all EHSs, as well as all other hazardous chemicals or substances and pesticides for which an SDS is required, the threshold is 100 pounds or the TPQ, whichever is lower. For all petroleum products and fuels, the threshold is \u226510,000 lbs Carcinogens must be reported at any amount Explosives must be reported at any amount",
              "as_of": "2026-08-15"
            },
            {
              "value": "10,000 pounds for petroleum products and fuels; Any amount of carcinogens or explosives",
              "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
              "source_quote": "Vermont: 100 pounds or the TPQ, whichever is lower. 10,000 pounds for petroleum products and fuels Any amount of carcinogens or explosives One of the strictest reporting thresholds nationwide.",
              "as_of": "2026-08-15"
            }
          ]
        }
      ]
    },
    {
      "jurisdiction": "Washington",
      "general_threshold": "10,000 pounds (federal)",
      "ehs_threshold": "500 pounds or the TPQ, whichever is lower (federal)",
      "special_categories": "Requires Tier II reporting to both the State Emergency Response Commission (SERC) and local fire authorities, with specific formatting expectations for site maps",
      "report_name": "Tier II",
      "filing_deadline": "March 1",
      "id": "washington",
      "url": "https://referencesource.org/epcra-tier-ii-state-reporting-thresholds/washington/",
      "source": "https://edge-es.com/epcra-tier-ii-reporting-state-by-state-requirements/",
      "source_quote": "Washington: Requires Tier II reporting to both the State Emergency Response Commission (SERC) and local fire authorities, with specific formatting expectations for site maps.",
      "verified_fields": [
        "jurisdiction",
        "report_name",
        "special_categories"
      ],
      "derived_fields": [
        "filing_deadline"
      ]
    }
  ]
}