# Scaffold measurement check — does the number I just measured meet OSHA 1926.451? Pick one of OSHA's numeric scaffold requirements, type the dimension you measured, and get a plain answer with the regulation's own sentence quoted and its paragraph cited. Every number here is quoted from 29 CFR 1926.451 itself. This is not a compliance determination and it is not legal advice: your competent person on site, and an OSHA inspector, decide whether a scaffold complies. This is the text version of an interactive page. The page itself is https://referencesource.org/apps/scaffold-measurement-check/ and it runs in a browser, working its answer out from what the person enters, so to answer for a particular person send them there. This file says what the page works from: the records, each with the sentence quoted from its source and a link to the record's own page, which has the values and marks any we could not find in that sentence. It is written automatically by Reference Source each time the site is built; nobody typed it. Every app here, as one text list with a link to each one's text version: https://referencesource.org/apps/index.md ## What it works from - [Every numeric requirement in OSHA's scaffold standard (29 CFR 1926.451) — dimensions, strengths, angles, safety factors and trigger heights](https://referencesource.org/osha-scaffold-dimensional-tolerances/): 91 of its records are named by id in this page's data. The dataset as text: https://referencesource.org/osha-scaffold-dimensional-tolerances/index.md - The data file exactly as the page loads it: https://referencesource.org/apps/scaffold-measurement-check/records.json (102,519 bytes; it holds 91 `records`) ## The records this page's data names (91) ### access-required-trigger-height (`access-required-trigger-height`) > (1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/access-required-trigger-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### crawling-board-grabline-minimum-diameter (`crawling-board-grabline-minimum-diameter`) > (iii) Each employee on a crawling board (chicken ladder) shall be protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board; Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/crawling-board-grabline-minimum-diameter/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### crossbrace-as-midrail-maximum-crossing-height (`crossbrace-as-midrail-maximum-crossing-height`) > (xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-as-midrail-maximum-crossing-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### crossbrace-as-midrail-minimum-crossing-height (`crossbrace-as-midrail-minimum-crossing-height`) > (xv) Crossbracing is acceptable in place of a midrail when the crossing point of two braces is between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-as-midrail-minimum-crossing-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### crossbrace-as-toprail-maximum-crossing-height (`crossbrace-as-toprail-maximum-crossing-height`) > as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-as-toprail-maximum-crossing-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### crossbrace-as-toprail-minimum-crossing-height (`crossbrace-as-toprail-minimum-crossing-height`) > as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-as-toprail-minimum-crossing-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### crossbrace-end-point-maximum-spacing (`crossbrace-end-point-maximum-spacing`) > The end points at each upright shall be no more than 48 inches (1.3 m) apart Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/crossbrace-end-point-maximum-spacing/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### direct-access-maximum-horizontal-distance (`direct-access-maximum-horizontal-distance`) > (8) Direct access to or from another surface shall be used only when the scaffold is not more than 14 inches (36 cm) horizontally Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/direct-access-maximum-horizontal-distance/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### direct-access-maximum-vertical-distance (`direct-access-maximum-vertical-distance`) > (8) Direct access to or from another surface shall be used only when the scaffold is not more than 14 inches (36 cm) horizontally and not more than 24 inches (61 cm) vertically from the other surface. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/direct-access-maximum-vertical-distance/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### end-frame-climbing-maximum-vertical-spacing (`end-frame-climbing-maximum-vertical-spacing`) > (iii) When erecting or dismantling tubular welded frame scaffolds, (end) frames, with horizontal members that are parallel, level and are not more than 22 inches apart vertically may be used as climbing devices for access, provided they are erected in a manner that creates a usable ladder and provides good hand hold and foot space. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/end-frame-climbing-maximum-vertical-spacing/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### fall-protection-trigger-height (`fall-protection-trigger-height`) > (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/fall-protection-trigger-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### float-scaffold-edging-minimum-dimensions (`float-scaffold-edging-minimum-dimensions`) > (ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below, except on float (ship) scaffolds where an edging of 3⁄4 × 11⁄2 inch (2 × 4 cm) wood or equivalent may be used in lieu of toeboards; Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/float-scaffold-edging-minimum-dimensions/index.md · last checked 2026-09-01 · due a re-check by 2027-09-01 ### handrail-minimum-clearance-from-objects (`handrail-minimum-clearance-from-objects`) > (vi) Handrails, and toprails that are used as handrails, shall be at least 3 inches (7.6 cm) from other objects. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/handrail-minimum-clearance-from-objects/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### height-to-base-ratio-tying-trigger (`height-to-base-ratio-tying-trigger`) > (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows: Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/height-to-base-ratio-tying-trigger/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### hoist-stall-load-maximum (`hoist-stall-load-maximum`) > (5) The stall load of any scaffold hoist shall not exceed 3 times its rated load. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/hoist-stall-load-maximum/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### hook-on-ladder-bottom-rung-maximum-height (`hook-on-ladder-bottom-rung-maximum-height`) > (ii) Hook-on and attachable ladders shall be positioned so that their bottom rung is not more than 24 inches (61 cm) above the scaffold supporting level; Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/hook-on-ladder-bottom-rung-maximum-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### hook-on-ladder-maximum-rung-spacing (`hook-on-ladder-maximum-rung-spacing`) > (vi) Hook-on and attachable ladders shall have uniformly spaced rungs with a maximum spacing between rungs of 163⁄4 inches. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/hook-on-ladder-maximum-rung-spacing/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### hook-on-ladder-minimum-rung-length (`hook-on-ladder-minimum-rung-length`) > (v) Hook-on and attachable ladders shall have a minimum rung length of 111⁄2 inches (29 cm); and Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/hook-on-ladder-minimum-rung-length/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### hook-on-ladder-rest-platform-interval (`hook-on-ladder-rest-platform-interval`) > (iii) When hook-on and attachable ladders are used on a supported scaffold more than 35 feet (10.7 m) high, they shall have rest platforms at 35-foot (10.7 m) maximum vertical intervals. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/hook-on-ladder-rest-platform-interval/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### intermediate-member-maximum-spacing (`intermediate-member-maximum-spacing`) > (vi) When intermediate members (such as balusters or additional rails) are used, they shall not be more than 19 inches (48 cm) apart. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/intermediate-member-maximum-spacing/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### load-safety-factor-scaffold-and-components (`load-safety-factor-scaffold-and-components`) > (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/load-safety-factor-scaffold-and-components/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### max-distance-to-work-face-general (`max-distance-to-work-face-general`) > (3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/max-distance-to-work-face-general/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### max-distance-to-work-face-outrigger (`max-distance-to-work-face-outrigger`) > (i) The maximum distance from the face for outrigger scaffolds shall be 3 inches (8 cm); Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/max-distance-to-work-face-outrigger/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### max-distance-to-work-face-plastering-lathing (`max-distance-to-work-face-plastering-lathing`) > (ii) The maximum distance from the face for plastering and lathing operations shall be 18 inches (46 cm). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/max-distance-to-work-face-plastering-lathing/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### midrail-minimum-strength-100-pound-systems (`midrail-minimum-strength-100-pound-systems`) > (ix) Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along the midrail or other member of at least 75 pounds (333 n) for guardrail systems with a minimum 100 pound toprail capacity, and at least 150 pounds (666 n) for guardrail systems with a minimum 200 pound toprail capacity. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/midrail-minimum-strength-100-pound-systems/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### midrail-minimum-strength-200-pound-systems (`midrail-minimum-strength-200-pound-systems`) > (ix) Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along the midrail or other member of at least 75 pounds (333 n) for guardrail systems with a minimum 100 pound toprail capacity, and at least 150 pounds (666 n) for guardrail systems with a minimum 200 pound toprail capacity. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/midrail-minimum-strength-200-pound-systems/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### min-platform-width-bracket-and-jack-scaffolds (`min-platform-width-bracket-and-jack-scaffolds`) > (i) Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold shall be at least 12 inches (30 cm) wide. There is no minimum width requirement for boatswains' chairs. Note to paragraph (b)(2)(i): Pursuant to an administrative stay effective November 29, 1996 and published in the Federal Register on November 25, 1996, the requirement in paragraph (b)(2)(i) that roof bracket scaffolds be at least 12 inches wide is stayed until November 25, 1997 or until rulemaking regarding the minimum width of roof bracket scaffolds has been completed, whichever is later. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/min-platform-width-bracket-and-jack-scaffolds/index.md · last checked 2026-10-01 · due a re-check by 2027-10-01 ### min-platform-width-general (`min-platform-width-general`) > (2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/min-platform-width-general/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### mobile-stairway-type-ladder-minimum-step-width (`mobile-stairway-type-ladder-minimum-step-width`) > except that mobile scaffold stairway-type ladders shall have a minimum step width of 111⁄2 inches (30 cm) Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/mobile-stairway-type-ladder-minimum-step-width/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### platform-gap-adjacent-units-and-uprights (`platform-gap-adjacent-units-and-uprights`) > (i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-gap-adjacent-units-and-uprights/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### platform-gap-to-uprights-demonstrated-exception (`platform-gap-to-uprights-demonstrated-exception`) > (ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 91⁄2 inches (24.1 cm). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-gap-to-uprights-demonstrated-exception/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### platform-maximum-deflection (`platform-maximum-deflection`) > (16) Platforms shall not deflect more than 1⁄60 of the span when loaded. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-maximum-deflection/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### platform-overhang-maximum-10-feet-or-less (`platform-overhang-maximum-10-feet-or-less`) > (i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-overhang-maximum-10-feet-or-less/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### platform-overhang-maximum-over-10-feet (`platform-overhang-maximum-over-10-feet`) > (ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-overhang-maximum-over-10-feet/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### platform-overhang-minimum (`platform-overhang-minimum`) > (4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-overhang-minimum/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### platform-overlap-minimum (`platform-overlap-minimum`) > (7) On scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/platform-overlap-minimum/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### powerline-clearance-insulated-300-volts-to-50-kv (`powerline-clearance-insulated-300-volts-to-50-kv`) > Insulated lines voltage | Minimum distance | Alternatives | Less than 300 volts | 3 feet (0.9 m) | | 300 volts to 50 kv | 10 feet (3.1m) | Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-insulated-300-volts-to-50-kv/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### powerline-clearance-insulated-over-50-kv (`powerline-clearance-insulated-over-50-kv`) > Insulated lines voltage | Minimum distance | Alternatives | Less than 300 volts | 3 feet (0.9 m) | | 300 volts to 50 kv | 10 feet (3.1m) | | More than 50 kv | 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv | 2 times the length of the line insulator, but never less than 10 feet (3.1 m). | Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-insulated-over-50-kv/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### powerline-clearance-insulated-under-300-volts (`powerline-clearance-insulated-under-300-volts`) > Insulated lines voltage | Minimum distance | Alternatives | Less than 300 volts | 3 feet (0.9 m) | Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-insulated-under-300-volts/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### powerline-clearance-uninsulated-over-50-kv (`powerline-clearance-uninsulated-over-50-kv`) > Uninsulated lines voltage | Minimum distance | Alternatives | Less than 50 kv | 10 feet (3.1 m) | | More than 50 kv | 10 feet (3.1 m) plus 0.4 inches (1.0 cm) for each 1 kv over 50 kv | 2 times the length of the line insulator, but never less than 10 feet (3.1 m). | Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-uninsulated-over-50-kv/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### powerline-clearance-uninsulated-under-50-kv (`powerline-clearance-uninsulated-under-50-kv`) > Uninsulated lines voltage | Minimum distance | Alternatives | Less than 50 kv | 10 feet (3.1 m) | Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/powerline-clearance-uninsulated-under-50-kv/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### prefabricated-access-frame-maximum-rung-spacing (`prefabricated-access-frame-maximum-rung-spacing`) > (6) Integral prefabricated scaffold access frames shall: (i) Be specifically designed and constructed for use as ladder rungs; (ii) Have a rung length of at least 8 inches (20 cm); (iii) Not be used as work platforms when rungs are less than 111⁄2 inches in length, unless each affected employee uses fall protection, or a positioning device, which complies with § 1926.502; (iv) Be uniformly spaced within each frame section; (v) Be provided with rest platforms at 35-foot (10.7 m) maximum vertical intervals on all supported scaffolds more than 35 feet (10.7 m) high; and (vi) Have a maximum spacing between rungs of 163⁄4 inches (43 cm). Non-uniform rung spacing caused by joining end frames together is allowed, provided the resulting spacing does not exceed 163⁄4 inches (43 cm). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/prefabricated-access-frame-maximum-rung-spacing/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### prefabricated-access-frame-minimum-rung-length (`prefabricated-access-frame-minimum-rung-length`) > (6) Integral prefabricated scaffold access frames shall: (i) Be specifically designed and constructed for use as ladder rungs; (ii) Have a rung length of at least 8 inches (20 cm); Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/prefabricated-access-frame-minimum-rung-length/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### prefabricated-access-frame-rest-platform-interval (`prefabricated-access-frame-rest-platform-interval`) > (v) Be provided with rest platforms at 35-foot (10.7 m) maximum vertical intervals on all supported scaffolds more than 35 feet (10.7 m) high; and Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/prefabricated-access-frame-rest-platform-interval/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### prefabricated-access-frame-work-platform-minimum-rung-length (`prefabricated-access-frame-work-platform-minimum-rung-length`) > (6) Integral prefabricated scaffold access frames shall: (i) Be specifically designed and constructed for use as ladder rungs; (ii) Have a rung length of at least 8 inches (20 cm); (iii) Not be used as work platforms when rungs are less than 111⁄2 inches in length Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/prefabricated-access-frame-work-platform-minimum-rung-length/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### ramp-walkway-cleat-maximum-spacing (`ramp-walkway-cleat-maximum-spacing`) > (iii) If the slope of a ramp or a walkway is steeper than one (1) vertical in eight (8) horizontal, the ramp or walkway shall have cleats not more than fourteen (14) inches (35 cm) apart which are securely fastened to the planks to provide footing. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/ramp-walkway-cleat-maximum-spacing/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### ramp-walkway-guardrail-trigger-height (`ramp-walkway-guardrail-trigger-height`) > (i) Ramps and walkways 6 feet (1.8 m) or more above lower levels shall have guardrail systems which comply with subpart M of this part Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/ramp-walkway-guardrail-trigger-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### ramp-walkway-maximum-slope (`ramp-walkway-maximum-slope`) > (ii) No ramp or walkway shall be inclined more than a slope of one (1) vertical to three (3) horizontal (20 degrees above the horizontal). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/ramp-walkway-maximum-slope/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### rope-replacement-broken-wires-per-rope-lay (`rope-replacement-broken-wires-per-rope-lay`) > Ropes shall be replaced if any of the following conditions exist: (i) Any physical damage which impairs the function and strength of the rope. (ii) Kinks that might impair the tracking or wrapping of rope around the drum(s) or sheave(s). (iii) Six randomly distributed broken wires in one rope lay Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-replacement-broken-wires-per-rope-lay/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### rope-replacement-broken-wires-per-strand (`rope-replacement-broken-wires-per-strand`) > Ropes shall be replaced if any of the following conditions exist: (i) Any physical damage which impairs the function and strength of the rope. (ii) Kinks that might impair the tracking or wrapping of rope around the drum(s) or sheave(s). (iii) Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope lay Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-replacement-broken-wires-per-strand/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### rope-replacement-outside-wire-diameter-loss (`rope-replacement-outside-wire-diameter-loss`) > (10) Ropes shall be inspected for defects by a competent person prior to each workshift and after every occurrence which could affect a rope's integrity. Ropes shall be replaced if any of the following conditions exist: (i) Any physical damage which impairs the function and strength of the rope. (ii) Kinks that might impair the tracking or wrapping of rope around the drum(s) or sheave(s). (iii) Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope lay. (iv) Abrasion, corrosion, scrubbing, flattening or peening causing loss of more than one-third of the original diameter of the outside wires. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-replacement-outside-wire-diameter-loss/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### rope-safety-factor-adjustable-suspension (`rope-safety-factor-adjustable-suspension`) > (4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-safety-factor-adjustable-suspension/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### rope-safety-factor-adjustable-suspension-stall-load (`rope-safety-factor-adjustable-suspension-stall-load`) > (4) Each suspension rope, including connecting hardware, used on adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope with the scaffold operating at either the rated load of the hoist, or 2 (minimum) times the stall load of the hoist, whichever is greater. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-safety-factor-adjustable-suspension-stall-load/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### rope-safety-factor-non-adjustable-suspension (`rope-safety-factor-non-adjustable-suspension`) > (3) Each suspension rope, including connecting hardware, used on non-adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/rope-safety-factor-non-adjustable-suspension/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### scaffold-stairway-minimum-width-between-stairrails (`scaffold-stairway-minimum-width-between-stairrails`) > (ix) Each scaffold stairway shall be at least 18 inches (45.7 cm) wide between stairrails. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/scaffold-stairway-minimum-width-between-stairrails/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stair-landing-platform-minimum-length (`stair-landing-platform-minimum-length`) > (viii) A landing platform at least 18 inches (45.7 cm) wide by at least 18 inches (45.7 cm) long shall be provided at each level. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stair-landing-platform-minimum-length/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stair-landing-platform-minimum-width (`stair-landing-platform-minimum-width`) > (viii) A landing platform at least 18 inches (45.7 cm) wide by at least 18 inches (45.7 cm) long shall be provided at each level. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stair-landing-platform-minimum-width/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stair-riser-height-maximum-variation (`stair-riser-height-maximum-variation`) > (xiii) Riser height shall be uniform, within 1⁄4 inch, (0.6 cm) for each flight of stairs. Greater variations in riser height are allowed for the top and bottom steps of the entire system, not for each flight of stairs. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stair-riser-height-maximum-variation/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stair-tread-depth-maximum-variation (`stair-tread-depth-maximum-variation`) > (xiv) Tread depth shall be uniform, within 1⁄4 inch, for each flight of stairs. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stair-tread-depth-maximum-variation/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stairrail-maximum-height (`stairrail-maximum-height`) > (vii) Stairrails shall be not less than 28 inches (71 cm) nor more than 37 inches (94 cm) from the upper surface of the stairrail to the surface of the tread, in line with the face of the riser at the forward edge of the tread. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stairrail-maximum-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stairrail-minimum-height (`stairrail-minimum-height`) > (vii) Stairrails shall be not less than 28 inches (71 cm) nor more than 37 inches (94 cm) from the upper surface of the stairrail to the surface of the tread, in line with the face of the riser at the forward edge of the tread. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stairrail-minimum-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stairtower-bottom-step-maximum-height (`stairtower-bottom-step-maximum-height`) > (4) Stairtowers (scaffold stairway/towers) shall be positioned such that their bottom step is not more than 24 inches (61 cm.) above the scaffold supporting level. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stairtower-bottom-step-maximum-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stairway-maximum-angle-from-horizontal (`stairway-maximum-angle-from-horizontal`) > (xi) Stairways shall be installed between 40 degrees and 60 degrees from the horizontal. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-maximum-angle-from-horizontal/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stairway-minimum-angle-from-horizontal (`stairway-minimum-angle-from-horizontal`) > (xi) Stairways shall be installed between 40 degrees and 60 degrees from the horizontal. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-minimum-angle-from-horizontal/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stairway-type-ladder-bottom-step-maximum-height (`stairway-type-ladder-bottom-step-maximum-height`) > (3) Stairway-type ladders shall: (i) Be positioned such that their bottom step is not more than 24 inches (61 cm) above the scaffold supporting level; Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-type-ladder-bottom-step-maximum-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stairway-type-ladder-minimum-step-width (`stairway-type-ladder-minimum-step-width`) > (3) Stairway-type ladders shall: (i) Be positioned such that their bottom step is not more than 24 inches (61 cm) above the scaffold supporting level; (ii) Be provided with rest platforms at 12 foot (3.7 m) maximum vertical intervals; (iii) Have a minimum step width of 16 inches (41 cm) Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-type-ladder-minimum-step-width/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### stairway-type-ladder-rest-platform-interval (`stairway-type-ladder-rest-platform-interval`) > (3) Stairway-type ladders shall: (i) Be positioned such that their bottom step is not more than 24 inches (61 cm) above the scaffold supporting level; (ii) Be provided with rest platforms at 12 foot (3.7 m) maximum vertical intervals; Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/stairway-type-ladder-rest-platform-interval/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### support-device-surface-factor-rated-load (`support-device-surface-factor-rated-load`) > (1) All suspension scaffold support devices, such as outrigger beams, cornice hooks, parapet clamps, and similar devices, shall rest on surfaces capable of supporting at least 4 times the load imposed on them by the scaffold operating at the rated load of the hoist (or at least 1.5 times the load imposed on them by the scaffold at the stall capacity of the hoist, whichever is greater). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/support-device-surface-factor-rated-load/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### support-device-surface-factor-stall-capacity (`support-device-surface-factor-stall-capacity`) > (1) All suspension scaffold support devices, such as outrigger beams, cornice hooks, parapet clamps, and similar devices, shall rest on surfaces capable of supporting at least 4 times the load imposed on them by the scaffold operating at the rated load of the hoist (or at least 1.5 times the load imposed on them by the scaffold at the stall capacity of the hoist, whichever is greater). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/support-device-surface-factor-stall-capacity/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### tie-horizontal-spacing-maximum (`tie-horizontal-spacing-maximum`) > Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/tie-horizontal-spacing-maximum/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### tie-vertical-spacing-narrow-scaffolds (`tie-vertical-spacing-narrow-scaffolds`) > be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/tie-vertical-spacing-narrow-scaffolds/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### tie-vertical-spacing-wide-scaffolds (`tie-vertical-spacing-wide-scaffolds`) > (ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/tie-vertical-spacing-wide-scaffolds/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### tipping-moment-factor-rated-load (`tipping-moment-factor-rated-load`) > (2) Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds, shall be capable of resisting at least 4 times the tipping moment imposed by the scaffold operating at the rated load of the hoist Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/tipping-moment-factor-rated-load/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### tipping-moment-factor-stall-load (`tipping-moment-factor-stall-load`) > (2) Direct connections to roofs and floors, and counterweights used to balance adjustable suspension scaffolds, shall be capable of resisting at least 4 times the tipping moment imposed by the scaffold operating at the rated load of the hoist, or 1.5 (minimum) times the tipping moment imposed by the scaffold operating at the stall load of the hoist, whichever is greater. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/tipping-moment-factor-stall-load/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toeboard-maximum-clearance-above-walking-surface (`toeboard-maximum-clearance-above-walking-surface`) > (ii) At least three and one-half inches (9 cm) high from the top edge of the toeboard to the level of the walking/working surface. Toeboards shall be securely fastened in place at the outermost edge of the platform and have not more than 1⁄4 inch (0.7 cm) clearance above the walking/working surface. Toeboards shall be solid or with openings not over one inch (2.5 cm) in the greatest dimension. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-maximum-clearance-above-walking-surface/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toeboard-maximum-opening-size (`toeboard-maximum-opening-size`) > Toeboards shall be solid or with openings not over one inch (2.5 cm) in the greatest dimension Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-maximum-opening-size/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toeboard-minimum-height (`toeboard-minimum-height`) > (ii) At least three and one-half inches (9 cm) high from the top edge of the toeboard to the level of the walking/working surface. Toeboards shall be securely fastened in place at the outermost edge of the platform and have not more than 1⁄4 inch (0.7 cm) clearance above the walking/working surface. Toeboards shall be solid or with openings not over one inch (2.5 cm) in the greatest dimension. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-minimum-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toeboard-minimum-strength (`toeboard-minimum-strength`) > (4) Where used, toeboards shall be: (i) Capable of withstanding, without failure, a force of at least 50 pounds (222 n) applied in any downward or horizontal direction at any point along the toeboard (toeboards built in accordance with appendix A to this subpart will be deemed to meet this requirement); and Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-minimum-strength/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toeboard-trigger-height (`toeboard-trigger-height`) > (ii) A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toeboard-trigger-height/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### top-tie-maximum-distance-from-top (`top-tie-maximum-distance-from-top`) > The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/top-tie-maximum-distance-from-top/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toprail-maximum-height-supported-after-2000 (`toprail-maximum-height-supported-after-2000`) > (ii) The top edge height of toprails or equivalent member on supported scaffolds manufactured or placed in service after January 1, 2000 shall be installed between 38 inches (0.97 m) and 45 inches (1.2 m) above the platform surface. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-maximum-height-supported-after-2000/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toprail-maximum-height-supported-before-2000-and-suspended (`toprail-maximum-height-supported-before-2000-and-suspended`) > The top edge height on supported scaffolds manufactured and placed in service before January 1, 2000, and on all suspended scaffolds where both a guardrail and a personal fall arrest system are required shall be between 36 inches (0.9 m) and 45 inches (1.2 m). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-maximum-height-supported-before-2000-and-suspended/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toprail-minimum-height-supported-after-2000 (`toprail-minimum-height-supported-after-2000`) > (ii) The top edge height of toprails or equivalent member on supported scaffolds manufactured or placed in service after January 1, 2000 shall be installed between 38 inches (0.97 m) and 45 inches (1.2 m) above the platform surface. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-minimum-height-supported-after-2000/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toprail-minimum-height-supported-before-2000-and-suspended (`toprail-minimum-height-supported-before-2000-and-suspended`) > The top edge height on supported scaffolds manufactured and placed in service before January 1, 2000, and on all suspended scaffolds where both a guardrail and a personal fall arrest system are required shall be between 36 inches (0.9 m) and 45 inches (1.2 m). Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-minimum-height-supported-before-2000-and-suspended/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toprail-minimum-strength-all-other-scaffolds (`toprail-minimum-strength-all-other-scaffolds`) > (vii) Each toprail or equivalent member of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) for guardrail systems installed on single-point adjustable suspension scaffolds or two-point adjustable suspension scaffolds, and at least 200 pounds (890 n) for guardrail systems installed on all other scaffolds. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-minimum-strength-all-other-scaffolds/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### toprail-minimum-strength-suspension-scaffolds (`toprail-minimum-strength-suspension-scaffolds`) > (vii) Each toprail or equivalent member of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) for guardrail systems installed on single-point adjustable suspension scaffolds or two-point adjustable suspension scaffolds, and at least 200 pounds (890 n) for guardrail systems installed on all other scaffolds. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/toprail-minimum-strength-suspension-scaffolds/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### walkway-guardrail-maximum-distance (`walkway-guardrail-maximum-distance`) > (v) Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 91⁄2 inches (24.1 cm) of and along at least one side of the walkway. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/walkway-guardrail-maximum-distance/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### welding-suspension-rope-insulation-minimum-extent (`welding-suspension-rope-insulation-minimum-extent`) > (17) To reduce the possibility of welding current arcing through the suspension wire rope when performing welding from suspended scaffolds, the following precautions shall be taken, as applicable: (i) An insulated thimble shall be used to attach each suspension wire rope to its hanging support (such as cornice hook or outrigger). Excess suspension wire rope and any additional independent lines from grounding shall be insulated; (ii) The suspension wire rope shall be covered with insulating material extending at least 4 feet (1.2 m) above the hoist. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/welding-suspension-rope-insulation-minimum-extent/index.md · last checked 2026-09-01 · due a re-check by 2027-09-01 ### winding-drum-hoist-minimum-rope-wraps (`winding-drum-hoist-minimum-rope-wraps`) > (6) When winding drum hoists are used on a suspension scaffold, they shall contain not less than four wraps of the suspension rope at the lowest point of scaffold travel. Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/winding-drum-hoist-minimum-rope-wraps/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### wire-rope-clip-minimum-spacing (`wire-rope-clip-minimum-spacing`) > (12) When wire rope clips are used on suspension scaffolds: (i) There shall be a minimum of 3 wire rope clips installed, with the clips a minimum of 6 rope diameters apart; Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/wire-rope-clip-minimum-spacing/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31 ### wire-rope-clips-minimum-number (`wire-rope-clips-minimum-number`) > (12) When wire rope clips are used on suspension scaffolds: (i) There shall be a minimum of 3 wire rope clips installed Source: Record: https://referencesource.org/osha-scaffold-dimensional-tolerances/wire-rope-clips-minimum-number/index.md · last checked 2026-08-31 · due a re-check by 2027-08-31